MIB Object
OID
Values
Description
copyEntryRowStatus
.1.3.6.1.4.1.6027.3.5.1.1.1.1.15
Row status
Specifies the state of the copy
operation. Uses CreateAndGo
when you are performing the
copy. The state is set to
active
when the copy is completed.
Obtaining a Value for MIB Objects
To obtain a value for any of the MIB objects, use the following command.
•
Get a copy-config MIB object value.
snmpset -v 2c -c public -m ./f10-copy-config.mib
force10system-ip-address
[
OID.index
|
mib-object.index
]
index
: the index value used in the
snmpset
command used to complete the copy operation.
NOTE: You can use the entire OID rather than the object name. Use the form:
OID.index
.
Examples of Getting MIB Object Values
The following examples show the
snmpget
command to obtain a MIB object value. These examples assume that:
•
the server OS is UNIX
•
you are using SNMP version 2c
•
the community name is public
•
the file f10-copy-config.mib is in the current directory
NOTE: In UNIX, enter the
snmpset
command for help using this command.
The following examples show the command syntax using MIB object names and the same command using the object OIDs. In both
cases, the same index number used in the
snmpset
command follows the object.
The following command shows how to get a MIB object value using the object name.
> snmpget -v 2c -c private -m ./f10-copy-config.mib 10.11.131.140 copyTimeCompleted.110
FTOS-COPY-CONFIG-MIB::copyTimeCompleted.110 = Timeticks: (1179831) 3:16:38.31
The following command shows how to get a MIB object value using OID.
> snmpget -v 2c -c private 10.11.131.140 .1.3.6.1.4.1.6027.3.5.1.1.1.1.13.110
SNMPv2-SMI::enterprises.6027.3.5.1.1.1.1.13.110 = Timeticks: (1179831) 3:16:38.31
MIB Support to Display the Available Memory Size on Flash
Dell Networking provides more MIB objects to display the available memory size on flash memory. The following table lists the MIB
object that contains the available memory size on flash memory.
Table 88. MIB Objects for Displaying the Available Memory Size on Flash via SNMP
MIB Object
OID
Description
chStackUnitFlashUsageUtil
1.3.6.1.4.1.6027.3.10.1.2.9.1.6
Contains flash memory usage in
percentage.
The chStackUnitUtilTable MIB table contains the chStackUnitFlashUsageUtil MIB object which contains the flash memory usage
percent. The chStackUnitUtilTable is located in f10SSerChassisMib MIB.
810
Simple Network Management Protocol (SNMP)
Содержание S4048-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 9 0 0 ...
Страница 146: ...Figure 14 BFD Three Way Handshake State Changes 146 Bidirectional Forwarding Detection BFD ...
Страница 477: ...Figure 68 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 477 ...
Страница 480: ...Figure 70 Inspecting a LAG Port on BRAVO Using the show interface Command 480 Link Aggregation Control Protocol LACP ...
Страница 481: ...Figure 71 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 481 ...
Страница 522: ...Figure 87 Configuring Interfaces for MSDP 522 Multicast Source Discovery Protocol MSDP ...
Страница 523: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 523 ...
Страница 524: ...Figure 89 Configuring PIM in Multiple Routing Domains 524 Multicast Source Discovery Protocol MSDP ...
Страница 528: ...Figure 91 MSDP Default Peer Scenario 1 528 Multicast Source Discovery Protocol MSDP ...
Страница 529: ...Figure 92 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 529 ...
Страница 530: ...Figure 93 MSDP Default Peer Scenario 3 530 Multicast Source Discovery Protocol MSDP ...
Страница 633: ...Policy based Routing PBR 633 ...
Страница 777: ...Figure 119 Single and Double Tag TPID Match Service Provider Bridging 777 ...
Страница 778: ...Figure 120 Single and Double Tag First byte TPID Match 778 Service Provider Bridging ...