Configuring Contact and Location Information using
SNMP
You may configure system contact and location information from the Dell Networking system or from the management station using
SNMP.
To configure system contact and location information from the Dell Networking system and from the management station using SNMP, use
the following commands.
•
(From a Dell Networking system) Identify the system manager along with this person’s contact information (for example, an email
address or phone number).
CONFIGURATION mode
snmp-server contact
text
You may use up to 55 characters.
The default is
None
.
•
(From a Dell Networking system) Identify the physical location of the system (for example, San Jose, 350 Holger Way, 1st floor lab, rack
A1-1).
CONFIGURATION mode
snmp-server location
text
You may use up to 55 characters.
The default is
None
.
•
(From a management station) Identify the system manager along with this person’s contact information (for example, an email address
or phone number).
CONFIGURATION mode
snmpset -v
version
-c
community agent-ip sysContact.0 s “contact-info”
You may use up to 55 characters.
The default is
None
.
•
(From a management station) Identify the physical location of the system (for example, San Jose, 350 Holger Way, 1st floor lab, rack
A1-1).
CONFIGURATION mode
snmpset -v
version
-c
community agent-ip sysLocation.0 s “location-info”
You may use up to 55 characters.
The default is
None
.
Subscribing to Managed Object Value Updates using
SNMP
By default, the Dell Networking system displays some unsolicited SNMP messages (traps) upon certain events and conditions.
You can also configure the system to send the traps to a management station. Traps cannot be saved on the system.
Dell Networking OS supports the following three sets of traps:
•
RFC 1157-defined traps
— coldStart, warmStart, linkDown, linkUp, authenticationFailure, and egpNeighbborLoss.
770
Simple Network Management Protocol (SNMP)
Содержание S3048-ON
Страница 1: ...Dell Configuration Guide for the S3048 ON System 9 11 2 5 ...
Страница 137: ...0 Gi 1 1 Gi 1 2 rx Flow N A N A 0 0 No N A N A yes Access Control Lists ACLs 137 ...
Страница 142: ...Figure 10 BFD Three Way Handshake State Changes 142 Bidirectional Forwarding Detection BFD ...
Страница 241: ...Dell Control Plane Policing CoPP 241 ...
Страница 287: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 287 ...
Страница 428: ...Figure 53 Inspecting the LAG Configuration 428 Link Aggregation Control Protocol LACP ...
Страница 429: ...Figure 54 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 429 ...
Страница 432: ...Figure 56 Inspecting a LAG Port on BRAVO Using the show interface Command 432 Link Aggregation Control Protocol LACP ...
Страница 433: ...Figure 57 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 433 ...
Страница 477: ...Figure 73 Configuring Interfaces for MSDP Multicast Source Discovery Protocol MSDP 477 ...
Страница 478: ...Figure 74 Configuring OSPF and BGP for MSDP 478 Multicast Source Discovery Protocol MSDP ...
Страница 479: ...Figure 75 Configuring PIM in Multiple Routing Domains Multicast Source Discovery Protocol MSDP 479 ...
Страница 483: ...Figure 77 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 483 ...
Страница 484: ...Figure 78 MSDP Default Peer Scenario 3 484 Multicast Source Discovery Protocol MSDP ...
Страница 634: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 634 Per VLAN Spanning Tree Plus PVST ...
Страница 745: ...Figure 104 Single and Double Tag TPID Match Service Provider Bridging 745 ...
Страница 746: ...Figure 105 Single and Double Tag First byte TPID Match 746 Service Provider Bridging ...