1. Replace the defective control module first, so the array has two good control modules.
2. Use the “restart” command to make the active control module secondary.
3. Replace the control module that is now secondary (was active before the restart). (As described in
the Secondary Control Module on page 40
.)
Replacing Both Control Modules
Use this procedure to replace both control modules in the array:
1. Replace the secondary control module first. (As described in
Replacing the Secondary Control Module on
.)
2. Use the “restart” command to make the active control module secondary.
3. Replace the control module that is now secondary (was active before the restart). (As described in
the Secondary Control Module on page 40
.)
Removing a Control Module
Before removing a control module from a PS-M4110 blade storage array:
•
Review the information at the beginning of
Replacing a Control Module on page 39
•
Attach an electrostatic wrist strap. See
Caution:
Do not remove an active control module.
Control modules are located in the large center slots of the array drawer. The control module slots are positioned
lengthwise between the storage drives, as shown in
Facing the front of the array drawer, the left-side control module is CM0 and the right-side control module is
CM1.