Steps
Align the power supply unit blank with the power supply unit slot and push it into the power supply
unit slot until it clicks into place.
Figure 86. Installing the PSU blank
1.
PSU blank
2. PSU bay
Related links
Safety instructions
Removing the power supply unit blank
Removing a redundant AC power supply unit
Replacing the power supply unit divider
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
1.
Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet and peripherals.
2.
If installed, remove the redundant power supply units (PSUs) or PSU blank.
Steps
1.
Remove the screw that secures the PSU divider to the chassis.
2.
Slide out the PSU divider and turn it clockwise to free the tabs on the PSU divider from the slots on
the PSU cage.
3.
Slide the PSU divider out of the chassis.
4.
Align the tabs of the new PSU divider with the slots of the PSU cage.
5.
Turn the PSU divider counterclockwise and slide it in until the PSU divider is seated on the slots of the
PSU cage.
6.
Tighten the screw to secure the PSU divider to the chassis.
179