About Your System
35
E2113
Mem mirror OFF
on DIMM ## &
##. Power
cycle AC
The system BIOS has
disabled memory
mirroring because it has
determined one half of the
mirror has had too many
errors. "## & ##"
represents the
memory-module pair
implicated by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 152.
I1910
Intrusion
detected.
Check chassis
cover.
System cover has been
removed.
Information only.
I1911
LCD Log Full.
Check SEL to
review all
Errors.
LCD overflow message.
A maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
I1912
SEL full.
Review & clear
log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for details
on the events, then clear
the SEL.
I1920
iDRAC6 Upgrade
Successful
optional iDRAC6 has
been upgraded
successfully.
Information only.
W1228
RAID
Controller
battery
capacity <
24hr.
Warns predictively that
the RAID battery has
less than 24 hours of
charge left.
Allow RAID battery to
charge to greater than
24 hours of
sustained charge.
If problem persists,
replace RAID battery.
See "Installing the RAID
Battery" on page 118."
Table 1-2.
LCD Status Messages (Optional)
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 35 Tuesday, March 31, 2009 5:26 PM
Содержание PowerEdge R410
Страница 1: ...Dell PowerEdge R410 Systems Hardware Owner s Manual ...
Страница 8: ...8 Contents ...
Страница 56: ...56 About Your System ...
Страница 78: ...78 Using the System Setup Program and UEFI Boot Manager ...
Страница 162: ...162 Troubleshooting Your System ...
Страница 168: ...168 Getting Help ...
Страница 174: ...174 Jumpers and Connectors ...
Страница 184: ...184 Glossary ...