About Your System
31
E1A15
SAS cable B
failure. Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 167.
E1A1D
Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 167.
E2010
Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules. See
"Installing Memory
Modules" on page 123 or
"Troubleshooting System
Memory" on page 152.
E2011
Memory
configuration
failure.
Check DIMMs.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
See "Troubleshooting
System Memory" on
page 152.
E2012
Memory
configured but
unusable.
Check DIMMs.
Memory configured, but is
unusable.
See "Troubleshooting
System Memory" on
page 152.
E2013
BIOS unable to
shadow memory.
Check DIMMs.
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 152.
E2014
CMOS RAM
failure. Power
cycle AC.
CMOS failure. CMOS
RAM not functioning
properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 167.
Table 1-2.
LCD Status Messages (Optional)
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 31 Tuesday, March 31, 2009 5:26 PM
Содержание PowerEdge R410
Страница 1: ...Dell PowerEdge R410 Systems Hardware Owner s Manual ...
Страница 8: ...8 Contents ...
Страница 56: ...56 About Your System ...
Страница 78: ...78 Using the System Setup Program and UEFI Boot Manager ...
Страница 162: ...162 Troubleshooting Your System ...
Страница 168: ...168 Getting Help ...
Страница 174: ...174 Jumpers and Connectors ...
Страница 184: ...184 Glossary ...