6
Troubleshooting
NOTE: To get help for your Dell PowerEdge Express Flash PCIe SSD, see
.
Self-Monitoring Analysis And Reporting Technology Errors
The PCIe SSD solution is always monitored for errors by its internal software. If an error occurs, it is detected and
recorded in an internal log. Based on the criticality of the error, the software may inform the host server that further
action is needed. It signifies that the error condition occurred a specific number of times and that the device health
needs attention.
PCIe SSD Carrier LED Indicators
The LEDs on the PCIe SSD carrier indicate the state of each physical device. Each PCIe SSD carrier in your enclosure
has an activity LED (green) and a status LED (bicolor, green/amber) as shown in the figure. The activity LED flashes
whenever the device is accessed.
Figure 8. PCIe SSD Device Carrier LED Indicators
1. activity indicator
2. status indicator
While the operating system is running, the status indicator provides the current status of the device. The table below
lists the device states along with the associated LED indicator codes.
Table 1. PCIe SSD States and LED Indicator Codes
State Name
Slot/Device State
Status LED (Green)
Status LED (Amber)
Device status off
OpenManage Server
Administrator is not
currently installed and
running in the system.
Off
Off
Device online
The device is powered up
and available for use by the
host operating system.
On
Off
29