![Dell PowerEdge C6320p Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/dell/poweredge-c6320p/poweredge-c6320p_owners-manual_85387061.webp)
Setting chassis type sticky bits for the PowerEdge C6320p sleds
Use the IPMI cmd: ipmitool –U server_user_name –P server_user_pass_word –H server IP –I lanplus raw 0x30 0xc8 0x00
0x0A 0x05 0x00 0x00 0x00 0x05 0x00 0x70 0x8e 0x02 to set the chassis type for the PowerEdge C6320p sled. For example:
To set chassis type for the PowerEdge C6320p sled execute this command
ipmitool –U server_user_name –P server_user_pass_word –H server IP –I lanplus raw 0x30
0xc8
0x00
0x0A 0x05 0x00 0x00 0x00 0x05 0x00
0x70 0x8e 0x02
Response:
0x0a 0x05 0x00 0x00 0x00
Checking the chassis type sticky bits for the PowerEdge C6320p sled
Use the IPMI cmd: ipmitool –U server_user_name –P server_user_pass_word –H server IP –I lanplus raw 0x30 0xc8 0x01
0x0A 0x05 0x00 0x00 0x00 to check if the chassis type is set for the PowerEdge C6320p sled. For example: To check if the
chassis type is set for the PowerEdge C6320p sled execute this command
ipmitool –U root –P calvin –H 10.3.25.127 –I lanplus raw 0x30 0xc8
0x01
0x0A 0x05 0x00
0x00 0x00
Response:
0x0a 0x05 0x00 0x00 0x00 0x5 0x00
0x70 0x8e 0x02
61
Содержание PowerEdge C6320p
Страница 1: ...Dell PowerEdge C6320p Owner s Manual Regulatory Model B08S Series Regulatory Type B08S004 ...
Страница 10: ...Figure 2 Supported configuration for the C6320p sled with an Intel Phi 72xx processor 10 ...
Страница 11: ...Figure 3 Supported configuration for the C6320p sled with an Intel Phi 72xx F processor 11 ...
Страница 25: ...Figure 16 Enclosure Service Tag location on the left front panel 25 ...
Страница 106: ...Figure 55 Removing an expansion card filler bracket 106 ...
Страница 152: ...Figure 95 Installing PDB 2 Figure 96 Installing the power cables and the power cable cover for PDB 2 152 ...