Connect expansion enclosure power cables
Steps
1. Connect the power cable to the power/cooling module:
Figure 17. Attaching power cable
2. Attach the retention bail (strain relief) to the base of the power cable.
The retention bail prevents the power cable from pulling out of the connection.
Cable the base enclosure to the new expansion enclosure
Follow these guidelines to cable the base enclosure in a running system to a new expansion enclosure.
Prerequisites
Apply cable labels to the cables connecting the expansion enclosures. In this procedure, "last expansion enclosure" refers to the
last expansion enclosure that is currently installed. The "new expansion enclosure" refers to the expansion enclosure that you
are adding in this procedure.
Steps
1. Disconnect the SAS cable from LCC B, port B of the last expansion enclosure and move it to LCC B, port B of the new
expansion enclosure.
2. Disconnect the SAS cable from LCC A, port B of the last expansion enclosure and move it to LCC A, port B of the new
expansion enclosure.
3. Use a new SAS cable to connect LCC A, port B of the last expansion enclosure to LCC A, port A of the new expansion
enclosure.
4. Use a new SAS cable to connect LCC B, port B of the last expansion enclosure to LCC B, port A of the new expansion
enclosure.
24
Install a new base enclosure and optional expansion enclosure