Configuring iDRAC6 Enterprise
51
FlexAddress MAC for iDRAC6
The FlexAddress feature replaces the server assigned MAC addresses with
chassis assigned MAC addresses and is now implemented for iDRAC6 along
with blade LOMs, mezzanine cards and I/O modules. iDRAC6 FlexAddress
feature supports preservation of slot specific MAC address for iDRAC6s in a
chassis. The chassis–assigned MAC address is stored in the CMC
non–volatile memory and is sent to iDRAC6 during iDRAC6 boot or if you
change the settings in the CMC FlexAddress page.
If CMC enables chassis–assigned MAC address, iDRAC6 displays the value in
the
MAC Address
field on the following screens:
•
System
→
Properties
tab
→
System Summary
→
iDRAC6 Information
•
System
→
Properties
tab
→
WWN/MAC
•
System
→
Remote Access
→
iDRAC6
→
Properties
tab
→
Remote Access
Information
→
Network Settings
•
System
→
Remote Access
→
iDRAC6
→
Network/Security
tab
→
Network
→
Network Interface Card Settings
CAUTION:
With the FlexAddress enabled, if you switch from server–assigned
MAC address to chassis–assigned MAC address and vice–versa, the iDRAC6 IP
address also changes.
NOTE:
You can enable or disable iDRAC6 FlexAddress feature only through CMC.
iDRAC6 GUI only reports the status. Any existing vKVM or vMedia session
terminates if the FlexAddress setting is changed in the CMC FlexAddress page.
Enabling FlexAddress through RACADM
NOTE:
You can not enable FlexAddress using
racadm setflexaddr -f idrac 1
where
iDRAC6 is one of the supported fabric names.
Enable FlexAddress at the slot level using the following CMC command
without the
–f
option.
1
Enable FlexAddress at the slot level by running the following CMC
RACADM command:
racadm setflexaddr -i <slot_no> 1
2
Next, enable FlexAddress at the fabric level by running the following CMC
RACADM command:
racadm setflexaddr -f <fabric_name> 1
Содержание IDRAC6
Страница 1: ...Integrated Dell Remote Access Controller 6 iDRAC6 Enterprise for Blade Servers Version 2 1 User Guide ...
Страница 38: ...38 iDRAC6 Enterprise Overview ...
Страница 84: ...84 Configuring the Managed Server ...
Страница 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Страница 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Страница 166: ...166 Configuring Smart Card Authentication ...
Страница 222: ...222 Using GUI Console Redirection ...
Страница 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Страница 270: ...270 Using the RACADM Command Line Interface ...
Страница 308: ...308 Using iDRAC6 Configuration Utility ...
Страница 334: ...334 Recovering and Troubleshooting the Managed System ...
Страница 382: ...382 RACADM Subcommand Overview ...
Страница 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Страница 462: ...462 Glossary ...
Страница 472: ...472 Index ...