182
Power Monitoring and Power Management
Power Consumption
•
Average Power Consumption
: Average over previous minute, previous
hour, previous day, and previous week.
•
Max Power Consumption
and
Min Power Consumption
: The maximum
and minimum power consumptions observed within the given time interval.
•
Max Power Time
and
Min Power Time
: The times (by minute, hour, day,
and week) when the maximum and minimum power consumptions occurred.
Show Graph
Click
Show Graph
to display graphs illustrating iDRAC6 power consumption
in Watts over the last hour, 24 hours, three days, and one week. Use the
drop-down menu provided above the graph to select the time period.
NOTE:
Each data point plotted on the graphs represents the average of readings
over a 5 minute period. As a result, the graphs may not reflect brief fluctuations in
power or current consumption.
Power Budgeting
The
Power Budget
screen displays the power threshold limits, which cover the
range of AC power consumptions a system under heavy workload will present to
the datacenter.
Before a server powers up, iDRAC6 provides CMC with its power envelope
requirement. It may request a smaller power envelope after the server is
powered up based on the actual power consumed by the server. If the power
consumption increases over time and if the server is consuming power near its
maximum allocation, iDRAC6 may request an increase of the maximum
potential power consumption thus increasing the power envelope. iDRAC6
only increases its maximum potential power consumption request to the
CMC. It does not request for a lesser minimum potential power if the
consumption decreases.
CMC reclaims any unused power from lower priority servers and
subsequently allocates the reclaimed power to a higher priority infrastructure
module or a server.
Содержание IDRAC6
Страница 1: ...Integrated Dell Remote Access Controller 6 iDRAC6 Enterprise for Blade Servers Version 2 1 User Guide ...
Страница 38: ...38 iDRAC6 Enterprise Overview ...
Страница 84: ...84 Configuring the Managed Server ...
Страница 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Страница 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Страница 166: ...166 Configuring Smart Card Authentication ...
Страница 222: ...222 Using GUI Console Redirection ...
Страница 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Страница 270: ...270 Using the RACADM Command Line Interface ...
Страница 308: ...308 Using iDRAC6 Configuration Utility ...
Страница 334: ...334 Recovering and Troubleshooting the Managed System ...
Страница 382: ...382 RACADM Subcommand Overview ...
Страница 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Страница 462: ...462 Glossary ...
Страница 472: ...472 Index ...