Enabled while server has default credential settings only
•
Enabled
For information about the fields, see the
iDRAC Settings Utility Online Help
.
4.
Click
Back
, click
Finish
and then click
Yes
to apply the settings.
Importing server configuration profile from USB device
Make sure to create a directory in root of the USB device called System_Configuration_XML which contains both the config.xml
and control.xml files:
•
Server Configuration Profile is in the System_Configuration_XML sub-directory under the USB device root directory. This file
includes all the attribute-value pairs of the server. This includes attributes of iDRAC, PERC, RAID, and BIOS. You can edit this file
to configure any attribute on the server. The file name can be <servicetag>-config.xml, <modelnumber>-config.xml, or
config.xml.
•
Control XML file – Includes parameters to control the import operation and does not have attributes of iDRAC or any other
component in the system. The control file contain three parameters:
– ShutdownType – Graceful, Forced, No Reboot.
– TimeToWait (in secs) – 300 minimum and 3600 maximum.
– EndHostPowerState – on/off.
Example of control.xml file:
<InstructionTable> <InstructionRow> <InstructionType>Configuration
XML import Host control Instruction</InstructionType>
<Instruction>ShutdownType</Instruction> <Value>NoReboot</
Value> <ValuePossibilities>Graceful,Forced,NoReboot</
ValuePossibilities> </InstructionRow> <InstructionRow>
<InstructionType>Configuration XML import Host control Instruction</
InstructionType> <Instruction>TimeToWait</Instruction>
<Value>300</Value> <ValuePossibilities>Minimum value is 300 -Maximum value
is 3600 seconds.</ValuePossibilities> </InstructionRow>
<InstructionRow> <InstructionType>Configuration XML import Host control
Instruction</InstructionType> <Instruction>EndHostPowerState</
Instruction> <Value>On</Value> <ValuePossibilities>On,Off</
ValuePossibilities> </InstructionRow></InstructionTable>
You must have Server Control privilege to perform this operation.
NOTE: While importing the server configuration profile, changing the USB management settings in the XML file results
in a failed job or job completed with errors. You can comment out the attributes in the XML to avoid the errors.
To import the server configuration profile from the USB device to iDRAC:
1.
Configure the USB management port:
•
Set
USB Management Port Mode
to
Automatic
or
iDRAC
.
•
Set
iDRAC Managed: USB XML Configuration
to
Enabled with default credentials
or
Enabled
.
2.
Insert the USB key (that has the configuration.xml and the control.xml file) to the iDRAC USB port.
3.
The server configuration profile is discovered on the USB device in the System_Configuration_XML sub-directory under the
USB device root directory. It is discovered in the following sequence:
•
<servicetag>-config.xml
•
<modelnum>-config.xml
•
config.xml
4.
A server configuration profile import job starts.
If the profile is not discovered, then the operation stops.
If
iDRAC Managed: USB XML Configuration
was set to
Enabled with default credentials
and the BIOS setup password is not
null or if one of the iDRAC user accounts have been modified, an error message is displayed and the operation stops.
5.
LCD panel and LED (if present) display the status that an import job has started.
272
Содержание iDRAC 7
Страница 1: ...iDRAC 8 7 v2 40 40 40 User s Guide ...
Страница 108: ...For more information see the iDRAC RACADM Command Line Interface Reference Guide available at dell com idracmanuals 108 ...
Страница 268: ...By default the logs are available at Event viewer Applications and Services Logs System 268 ...