The
Current Value
column displays the existing values for each property. You can modify this value by selecting the option
from the
Action
drop-down menu for each property.
For information about the fields, see the
iDRAC Online Help
.
4.
From the
Apply Operation Mode
drop-down menu, select when you want to apply the settings.
5.
Click
Apply
.
Based on the selected operation mode, the settings are applied.
Configuring controller properties using RACADM
•
To set Patrol Read Mode:
racadm set storage.controller.<index>.PatrolReadMode {Automatic | Manual | Disabled}
•
If Patrol read mode is set to manual, use the following commands to start and stop Patrol read Mode:
racadm storage patrolread:<Controller FQDD> -state {start|stop}
NOTE: Patrol read mode operations such as Start and Stop are not supported if there are no virtual disks available in
the controller. Though you can invoke the operations successfully using the iDRAC interfaces, the operations will fail
when the associated job is started.
•
To specify the Check Consistency Mode, use
Storage.Controller.CheckConsistencyMode
object.
•
To enable or disable the Copyback Mode, use
Storage.Controller.CopybackMode
object.
•
To enable or disable the Load Balance Mode, use
Storage.Controller.PossibleloadBalancedMode
object.
•
To specify the percentage of the system's resources dedicated to perform a check consistency on a redundant virtual disk, use
Storage.Controller.CheckConsistencyRate
object.
•
To specify the percentage of the controller's resources dedicated to rebuild a failed disk, use
Storage.Controller.RebuildRate
object
•
To specify the percentage of the controller's resources dedicated to perform the background initialization (BGI) of a virtual disk
after it is created, use
Storage.Controller.BackgroundInitializationRate
object
•
To specify the percentage of the controller's resources dedicated to reconstruct a disk group after adding a physical disk or
changing the RAID level of a virtual disk residing on the disk group, use
Storage.Controller.ReconstructRate
object
•
To enable or disable the enhanced auto import of foreign configuration for the controller, use
Storage.Controller.EnhancedAutoImportForeignConfig
object
•
To create, modify, or delete security key to encrypt virtual drives:
racadm storage createsecuritykey:<Controller FQDD> -key <Key id> -passwd <passphrase>
racadm storage modifysecuritykey:<Controller FQDD> -key <key id> -oldpasswd <old
passphrase> -newpasswd <new passphrase>
racadm storage deletesecuritykey:<Controller FQDD>
Importing or auto importing foreign configuration
A foreign configuration is data residing on physical disks that have been moved from one controller to another. Virtual disks residing
on physical disks that have been moved are considered to be a foreign configuration.
You can import foreign configurations so that virtual disks are not lost after moving Physical Disks. A foreign configuration can be
imported only if it contains a virtual disk that is in either Ready or Degraded state or a hotspare that is dedicated to a virtual disk
which can be imported or is already present.
All of the virtual disk data must be present, but if the virtual disk is using a redundant RAID level, the additional redundant data is not
required.
For example, if the foreign configuration contains only one side of a mirror in a RAID 1 virtual disk, then the virtual disk is in a
Degraded state and can be imported. If the foreign configuration contains only one physical disk that was originally configured as a
RAID 5 using three physical disks, then the RAID 5 virtual disk is in a Failed state and cannot be imported.
In addition to virtual disks, a foreign configuration may consist of a physical disk that was assigned as a hot spare on one controller
and then moved to another controller. The Import Foreign Configuration task imports the new physical disk as a hot spare. If the
206