12
|
System Overview
www.dell.com | support.dell.com
NOTE:
As suggested by the footnote above, the fiber SFP ports have priority over the four 10/100/1000 ports
with the same number.
The following table describes the LED status indicators on the left side of the front panel.
*The four XFP LEDs on the front panel also indicate the status when CX4 ports are installed in the bay.
Table 2-2. Status Panel LED Display
Label
LED Color
Description
Left Side of the Status Panel
OK
Green
Off
Green Blinking
Amber
Unit is online.
Unit is powered off.
Unit is booting up. (blinking rate is 16 Hz)
Error during boot-up.
AC (on the S50V
and S50N)
DC1 (on the
S50N-DC)
Green
Amber
Off
Power supply is present and OK.
Power supply is present but failed.
Power supply is not present.
XFP49*
Green
Blinking Green
Off
A valid 10G link is established on the port.
Transmitting or receiving packets on the port.
No link is established on the port.
XFP50*
Green
Blinking Green
Off
A valid 10G link is established on the port.
Transmitting or receiving packets on the port.
No link is established on the port.
STACK ID
Green
Indicates the stack ID (sometimes called "switch ID") of the unit.
Starting with FTOS 7.8.1.0:
• “
A
” is displayed to the left of the stack ID if the unit is a standalone or
master (management) unit.
• “
B
” is displayed for a standby unit. (Actually, it’s an 8, because of the
limitations of the 7-segment LED.)
• “
0
” is displayed next to the stack ID, as before, for the other units.
Right Side of the Status Panel
Alarm
Amber
Red
Off
Minor alarm: Fan or temperature is operating outside parameters.
Major alarm
No alarm
DC (on the S50V
and S50N)
DC2 (on the
S50N-DC)
Green
Amber
Off
Power supply is present and OK.
Power supply is present but failed.
Power supply is not present.
XFP51*
Green
Blinking Green
Off
A valid 10G link is established on the port.
Transmitting or receiving packets on the port.
No link is established on the port.
XFP52*
Green
Blinking Green
Off
A valid 10G link is established on the port.
Transmitting or receiving packets on the port.
No link is established on the port.
Содержание Force10 S50N Series
Страница 1: ...Installing S50N and S50V Systems ...
Страница 8: ...8 About this Guide w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 40: ...40 Installing Backup Power w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 46: ...46 Installing Ports w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 58: ...58 Technical Support w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 63: ......
Страница 64: ...w w w d ell com support dell com Printed in the U S A ...