background image

Dell Force10 S25 Systems

Quick Start Guide

Regulatory Model: 
S25N/S25V/S25P

Содержание Force10 S25 Series

Страница 1: ...Dell Force10 S25 Systems Quick Start Guide Regulatory Model S25N S25V S25P ...

Страница 2: ......

Страница 3: ...Dell Force10 S25 Systems Quick Start Guide Regulatory Model S25N S25V S25P ...

Страница 4: ...es AMD is a registered trademark and AMD Opteron AMD Phenom and AMD Sempron are trademarks of Advanced Micro Devices Inc Microsoft Windows Windows Server MS DOS and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation inthe United States and or other countries Red Hat Enterprise Linux and Enterprise Linux are registered trademarks of Red Hat Inc in the United State...

Страница 5: ... the following documents Documentation S25N S25V S25P Hardware installation and power up instructions Installing S25N and S25V Systems Installing the S25P System Software configuration FTOS Configuration Guide FTOS Configuration Guide Command line interface FTOS Command Line Reference Guide FTOS Command Line Reference Guide Latest updates FTOS Release Notes for the S Series FTOS Release Notes for ...

Страница 6: ...4 About this Guide ...

Страница 7: ...vices of this type take all necessary safety precautions to prevent injury when installing this system Electrostatic discharge ESD damage can occur if components are mishandled Installing a Chassis in a Two Post Rack The chassis is shipped with the universal front mounting brackets rack ears attached Ensure that there is adequate clearance surrounding the rack to permit access and airflow The S25 ...

Страница 8: ...le a second person attaches the brackets to the posts 2 Position the unit in the rack Secure the unit with two of the supplied screws through each bracket and onto the rack post S25N V S25P P28 27 XFP 26 AC XFP 25 DC Ala rm STA CK ID S50 01 GE 24V P28 27 XFP 26 AC1 XFP 25 AC2 Alar m Stac k ID S25 01 G E 24 P ...

Страница 9: ...nsure an adequate unit ground Install the SFP and XFP Optics The S25 chassis have four receptacles on the I O side that accommodate 10 100 1000 SFP optical transceivers Additionally the S25 has bays on the PSU side that accommodate optional CX4 or XFP modules A 10GbE module contains two ports 10GbE modules should only be inserted or removed when the switch is powered down SFP and XFP transceivers ...

Страница 10: ...hen working with optical fibers Always wear eye protection when working with optical fibers Never look directly into the end of a terminated or unterminated fiber or connector as it may cause eye damage Step Task 1 Position the SFP so it is in the upright position The SFP optic has a key that prevents it from being inserted incorrectly 2 Insert the SFP into the port until it gently snaps into plac...

Страница 11: ...ou can also disconnect and remove XFP transceivers while the switch is operating However inserting or removing the module is not supported it can crash or lock up the switch requiring a reboot CAUTION The CX4 module does not use transceivers However you can use a CX4 cable with an XFP port by inserting a CX4 XFP converter catalog name GP XFP 1CX4 into the slot An XFP port does not support the use ...

Страница 12: ...or act in load sharing mode S25V The S25V has both an AC 3 prong plug receptacle and a DC 48V terminal type connection on the PSU side of the unit Each power source can be used independently or in load sharing combination In other words you have three options for providing power to the switch AC only DC only or using both AC and DC sources To use AC only connect the supplied AC power cord first to...

Страница 13: ...cables to the switch terminals and then to the remote power sources 4 Replace the safety covers on the DC terminal block Step Task 1 Make sure that the remote power source the circuit breaker panel is in the OFF position 2 Remove the safety cover from the DC terminal block 3 Connect the grounding cable to the FG terminal first then connect the opposite end to the appropriate grounding point at you...

Страница 14: ...ectly excessive emissions may result Use a qualified electrician to ensure that the power cables meet your local electrical requirements Fans Ventilation is side to side on the switch as you face the I O side The fans operate at a constant speed and with automatic speed adjustment for temperature changes For the S25N and S25V FTOS turns on major and minor alarms and logs temperature warnings at th...

Страница 15: ... cm Front 5 inches 12 7 cm Rear 5 inches 12 7 cm Parameter S25N V Specifications S25P Specifications Temperature 32 to 122 F 0 to 50 C 40 to 158 F 40 to 70 C non operating storage temperature 32 to 122 F 0 to 50 C 40 to 158 F 40 to 70 C non operating storage temperature Maximum Thermal Output S25N 349 05 BTU Hour S25V 349 05 BTU Hour S25P 305 BTU Hour S25P DC 262 BTU Hour Maximum altitude No perfo...

Страница 16: ...0 254 VAC 47 63 Hz S25P 90 254 VAC 47 63 Hz S25P DC 48 VDC Maximum Current Draw S25N 2 A 100 120 VAC 1 A 200 240 VAC S25V AC 6 5 A 100 120 VAC 3 25A 200 240 VAC S25V DC 11 5A 48 VDC S25P 2 A 100 120 VAC 1 A 200 240 VAC S25P DC 3 6 A 48 VDC Minimum AC Current Draw 35 A 254 VAC 62 A 90 VAC 25 A 254 VAC 56 A 90 VAC Maximum power consumption S25N S25V 102W S25N AC 156W S25N DC 136W S25P 90W S25P DC 77...

Страница 17: ...el Console Access Access the command line through a serial console port or a Telnet session When the system successfully boots you enter the command line in the EXEC mode NOTE You must have a password configured on a virtual terminal line before you can Telnet into the system Therefore you must use a console connection when connecting to the system for the first time Serial Console The RS 232 cons...

Страница 18: ...le If connecting to a terminal server and using a crossover cable daisychain another crossover cable to effectively get a straight through cable connection Many console terminal servers use octopus cables that are crossover cables To accommodate the octopus cable connect an additional crossover cable as above to effectively install a straight through cable 2 If necessary connect the RJ 45 DB 9 ada...

Страница 19: ...y the settings to match at each end of the connection 4 S25P only If you use the console port to download software to the switch you will probably want to raise the console baud rate Establish a connection with the default settings to verify the connection Then use the lineconfig command to access the Line Config mode and use the serial baudrate command to raise the baud rate on the console port M...

Страница 20: ... spanning tree protocol on an interface unless the interface has been set to Layer 2 mode To view the interfaces in Layer 2 mode use the show interfaces switchport command in the EXEC mode Configure a Host Name The host name appears in the prompt The default host name is Force10 Host names must start with a letter and end with a letter or digit Characters within the string can be letters digits an...

Страница 21: ... system to the network from which you are accessing the system remotely Management routes are separate from IP routes and are only used to manage the system through the management port Step Task Command Syntax Command Mode 1 Configure an IP address for the port through which you will manage the system ip address INTERFACE 2 Configure an IP route with a default gateway ip route CONFIGURATION 3 Conf...

Страница 22: ...ion using a DES encryption method enable secret is stored in the running startup configuration in using a stronger MD5 encryption method Dell Force10 recommends using the enable secret password Task Command Syntax Command Mode Configure a management route to the network from which you are accessing the system management route ip address mask gateway CONFIGURATION Task Command Syntax Command Mode C...

Страница 23: ...haps multiple VLANs Untagged Ports ports that do not append an 802 1Q VLAN tag to frames on egress and do not accept tagged frames on ingress tagged frames are dropped Untagged ports must be connected to VLAN unaware devices Tagged Ports ports that append an 802 1Q tag to frames on egress and accept only tagged frames on ingress untagged frames are dropped Tagged ports must be connected to VLAN aw...

Страница 24: ...completed the hardware installation and software configuration you can connect to your company network by following your company s cabling requirements Step Task Command Syntax Command Mode 1 Assign a switchport to a VLAN tagged untagged interface INTERFACE VLAN 2 Display all switchports and the VLANs of which they are members show vlan EXEC Privilege Task Command Syntax Command Mode Configure an ...

Страница 25: ......

Страница 26: ...www dell com support dell com Printed in the U S A ...