select it in the Storage Pool (for more information on Storage Pool, see "Storage
Pools").
FG enables data compression which allows for faster reads and writes. Data-
compression is not supported for Medium Granularity (MG). It supports thin
provisioned, zero padded volumes. Zero padded is enabled by default for FG and can't
be disabled. Zero padding is disabled for MG.
FG supports persistent checksum for data integrity. For more information on
persistent checksum, see "Checksum protection".
Volumes
You must add and configure volumes before enabling applications to access them.
The adding and mapping volume process is necessary, as part of the getting started
process, before applications can access the volumes. In addition, you may create
additional volumes and map them as part of the maintenance of the virtualization
layer.
You can configure the caching option when creating the volumes, or you can change
the Read RAM Cache feature later. If you want to enable the caching feature, ensure
that the feature is also enabled in the backend of the system, for the corresponding
Storage Pool and SDSs. For more information, see "Change Read RAM Cache volume
settings".
Define volume names according to the following rules:
l
Contains less than 32 characters
l
Contains only alphanumeric and punctuation characters
l
Is unique within the object type
VxFlex OS objects are assigned a unique ID that can be used to identify the object in
CLI commands. You can retrieve the ID via a query, or via the object’s property sheet
in the VxFlex OS GUI. It is highly recommended to give each volume a meaningful
name associated with its operational role.
Naming
Giving meaningful names to VxFlex OS objects can simplify volume-related actions.
It is recommended to name all VxFlex OS objects with meaningful names. This will
make it easier when defining volumes, associating them with applications, etc.
From the previous example, the Storage Pools can be named "Capacity_Storage" and
"Performance_Storage," which allows you to identify the different tiers.
As for Protection Domains, one example would be separating the SDSs used by the
finance department from those used by the engineering department. This segregation
of different departments is very beneficial in many aspects (security being one of
them). Thus, one might name the domains "Financial-PD" and "Engineering-PD."
The Fault Sets could be called "FS_Rack01" and "FS_Rack02."
Protection and load balancing
VxFlex OS maintains the user data in a RAID-1 mesh mirrored layout. Each piece of
data is stored on two different servers. The copies are randomly distributed over the
storage devices. Rebuild and rebalance processes are fully automated, but are
configurable.
Architecture
Dell EMC VxFlex Ready Node AMS User Guide
33
Содержание EMC VxFlex Ready Node
Страница 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Страница 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...
Страница 354: ...Glossary 354 Dell EMC VxFlex Ready Node AMS User Guide ...