Figure 25 B13 sliding rail assembly - 2U systems (continued)
3. screw (4)
4. washer (4)
Install the rails
About this task
The rails are labeled left and right, and cannot be interchanged. The front side of each rail is labeled Left Front or
Right Front when viewed from the cabinet front.
Procedure
1.
Determine where to mount the system, and use masking tape or a felt-tip pen to mark the location at the front
and back of the cabinet.
Note:
Install the left rail assembly first.
2.
Fully extend the rear sliding bracket of the rail.
3.
Position the rail end piece labeled Left Front facing inward and orient the rear end piece to align with the holes
on the rear cabinet flanges.
4.
Push the rail straight toward the rear of the rack until the latch locks in place.
Figure 26 Installing the rear end of the rail
5.
For the front end piece, rotate the latch outward and pull the rail forward until the pins slide into the flange, and
release the latch to secure the rail in place.
R740XD Configuration Equipment Installation
Dell EMC VxFlex Ready Node Server Installation Guide
61
Содержание EMC VxFlex Ready Node
Страница 1: ...Dell EMC VxFlex Ready Node Server Installation Guide Rev 01 October 2019 ...
Страница 6: ...Figures 6 Dell EMC VxFlex Ready Node Server Installation Guide ...
Страница 8: ...Tables 8 Dell EMC VxFlex Ready Node Server Installation Guide ...
Страница 16: ...Before You Begin 16 Dell EMC VxFlex Ready Node Server Installation Guide ...
Страница 18: ...R640 Procedures 18 Dell EMC VxFlex Ready Node Server Installation Guide ...
Страница 56: ...R740XD Procedures 56 Dell EMC VxFlex Ready Node Server Installation Guide ...
Страница 80: ...R840 Procedures 80 Dell EMC VxFlex Ready Node Server Installation Guide ...