Table 44 Drive indicator codes (continued)
Drive status indicator code
Condition
Flashes green slowly
Drive rebuilding.
Solid green
Drive online.
Flashes green for three seconds, amber for
three seconds, and then turns off after six
seconds
Rebuild stopped.
Using system diagnostics
If you experience a problem with your system, run the system diagnostics before
contacting Dell EMC for technical assistance. The purpose of running system
diagnostics is to test your system hardware without using additional equipment or
risking data loss. If you are unable to fix the problem yourself, service and support
personnel can use the diagnostics results to help you solve the problem.
Dell Embedded System Diagnostics
Note
The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System
Assessment (ePSA) diagnostics.
The Embedded System Diagnostics provides a set of options for particular device
groups or devices allowing you to:
l
Run tests automatically or in an interactive mode
l
Repeat tests
l
Display or save test results
l
Run thorough tests to introduce additional test options to provide extra
information about the failed device(s)
l
View status messages that inform you if tests are completed successfully
l
View error messages that inform you of problems encountered during testing
Running the Embedded System Diagnostics from Boot Manager
Run the Embedded System Diagnostics (ePSA) if your system does not boot.
Procedure
1. When the system is booting, press F11.
2. Use the up arrow and down arrow keys to select System Utilities
>
Launch
Diagnostics.
3. Alternatively, when the system is booting, press F10, select Hardware
Diagnostics
>
Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all
devices detected in the system. The diagnostics starts executing the tests on all
the detected devices.
System diagnostics and indicator codes
Using system diagnostics
213