Note
Observe the routing of the cables as you remove them from the system. You
must route the cables properly when you replace them to prevent the cables
from being pinched or crimped.
2. Using a Phillips #2 screwdriver, remove the screw securing the PIB to the
system.
3. Holding the blue touch point on the PIB, gently lift, to release it from the PSU
cage, and slide it out.
4. Lift the PIB away from the system.
Figure 72 Removing power interposer board
Install the power interposer board
Before you begin
Follow all safety guidelines.
CAUTION
To prevent damage to the power interposer board, you must remove the power
supply module (s) or power supply blank from the system before removing the
power interposer board or power distribution board.
Note
Ensure that the cables inside the system are correctly routed and secured using the
cable securing latches.
Procedure
1. Align and push the PIB to the PSU cage and slide it into place.
2. Using a Phillips #2 screwdriver, tighten the screw to secure the PIB to the
system.
Hardware FRU procedures
Install the power interposer board
155