
Table 4. iDRAC Quick Sync 2 indicators and descriptions
iDRAC Quick Sync 2 indicator
code
Condition
Corrective action
Off (default state)
Indicates that the iDRAC Quick Sync 2
feature is turned off. Press the iDRAC Quick
Sync 2 button to turn on the iDRAC Quick
Sync 2 feature.
If the LED fails to turn on, reseat the left control panel
flex cable and check. If the problem persists, see the
Getting help section.
Solid white
Indicates that iDRAC Quick Sync 2 is ready
to communicate. Press the iDRAC Quick
Sync 2 button to turn off.
If the LED fails to turn off, restart the system. If the
problem persists, see the Getting help section.
Blinks white rapidly
Indicates data transfer activity.
If the indicator continues to blink indefinitely, see the
Getting help section.
Blinks white slowly
Indicates that firmware update is in
progress.
If the indicator continues to blink indefinitely, see the
Getting help section.
Blinks white five times rapidly and
then turns off
Indicates that the iDRAC Quick Sync 2
feature is disabled.
Check if iDRAC Quick Sync 2 feature is configured to
be disabled by iDRAC. If the problem persists, see the
Getting help section. For more information, see
Integrated Dell Remote Access Controller User's
Guide
at
Dell.com/idracmanuals
or
Dell
OpenManage Server Administrator User’s Guide
at
Dell.com/openmanagemanuals
.
Solid amber
Indicates that the system is in fail-safe
mode.
Restart the system. If the problem persists, see the
Getting help section.
Blinking amber
Indicates that the iDRAC Quick Sync 2
hardware is not responding properly.
Restart the system. If the problem persists, see the
Getting help section.
Right control panel view
Figure 7. Right control panel
Dell EMC PowerEdge R440 overview
11