Table 3. Switch port numbers
Switch
Port number
Description
Hare
1-16
Data network ports connected to nodes (10/25 GbE)
17-40
Not designated
41-48
Customer uplink ports (10/25 GbE)
49-50
VLT ports (100 GbE)
51-54
Customer uplink ports (100 GbE)
Rabbit
1-16
Data network ports connected to nodes (10/25 GbE)
17-40
Not designated
41-48
Customer uplink ports (10/25 GbE)
49-50
VLT ports (100 GbE)
51-54
Customer uplink ports (100 GbE)
Back-end switch pair
Dell EMC provides two 25 GbE S5148F back-end switches (BE1 and BE2) with two 100 GbE VLT cables. These switches are
referred to as the Hound (BE2) and Fox (BE1) switches.
In the following diagram, all labeled ports relate to an ECS virtual data center (VDC) in which all racks/nodes are EX-Series
(Gen3 hardware), with the exception of ports 39 and 40. Ports 39 and 40 are only used in the scenario where there is Gen2
hardware series integration with EX-Series hardware in the VDC. When Gen2 hardware is mixed with EX-Series hardware, ports
39 and 40 are the only ports used for connectivity.
All iDRAC cables from nodes and all front-end switch management cable connections route to the Fox (BE1) switch.
Fox Switch (BE1)
Hound Switch (BE2)
1
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
4
6
2
3
5
7
9
11 13 15
17 19 21 23 25 27 29
35
31 33
37 39 41 43 45 47
1
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
4
6
2
3
5
7
9
11 13 15
17 19 21 23 25 27 29
35
31 33
37 39 41 43 45 47
49 51 53
49 51 53
50 52 54
50 52 54
Figure 3. Back-end switches
Table 4. Switch port number
Switch
Port number
Description
Hound
1-16
Private network ports connected to nodes (10/25 GbE)
17-40
Not designated.
41-44
In from EX-Series rack when the ECS system has more than one rack (10/25 GbE)
45-48
Out to EX-Series rack when the ECS system has more than one rack (10/25 GbE)
49-50
VLT ports (100 GbE)
51-54
Not designated (100 GbE)
12
Switches
Содержание ECS EX Series
Страница 1: ...ECS EXSeries Hardware Guide 3 5 June 2021 Rev 1 2 ...
Страница 15: ...Figure 6 Front end switch connections to customer switches example Switches 15 ...
Страница 31: ...EX500 Platform 31 ...
Страница 32: ...Figure 16 EX500 Three Phase Delta AC Cabling Diagram 32 EX500 Platform ...
Страница 33: ...Figure 17 EX500 Three Phase Wye AC Cabling Diagram EX500 Platform 33 ...
Страница 42: ...Figure 26 EX500 network cabling 42 EX500 Platform ...
Страница 58: ...Figure 43 EX300 single phase AC power cabling 58 EX300 Platform ...
Страница 59: ...Figure 44 ECSv3 740xd Single Phase AC Cabling Diagram EX300 Platform 59 ...
Страница 60: ...Figure 45 Three phase Delta AC power cabling 60 EX300 Platform ...
Страница 61: ...Figure 46 ECSv3 740xd Three Phase Delta AC Cabling Diagram EX300 Platform 61 ...
Страница 62: ...Figure 47 Three phase WYE AC power cabling 62 EX300 Platform ...
Страница 63: ...Figure 48 ECSv3 740xd Three Phase Wye AC Cabling Diagram EX300 Platform 63 ...
Страница 65: ...Figure 50 iDRAC cabling EX300 Platform 65 ...
Страница 71: ...Figure 57 EX300 network cabling EX300 Platform 71 ...
Страница 78: ...Figure 66 EX3000S minimum and maximum configurations for single node chassis 78 EX3000 Platform ...
Страница 82: ...Server front view Figure 68 EX3000 server front view in rack 82 EX3000 Platform ...
Страница 91: ...Figure 78 EX3000S single phase AC power cabling EX3000 Platform 91 ...
Страница 92: ...Figure 79 EX3000D single phase AC power cabling 92 EX3000 Platform ...
Страница 94: ...Figure 81 EX3000S three phase delta AC power cabling 94 EX3000 Platform ...
Страница 95: ...Figure 82 EX3000D three phase delta AC power cabling EX3000 Platform 95 ...
Страница 96: ...Figure 83 EX3000S three phase WYE AC power cabling 96 EX3000 Platform ...
Страница 97: ...Figure 84 EX3000D three phase WYE AC power cabling EX3000 Platform 97 ...
Страница 101: ...Figure 86 EX3000D iDRAC cabling EX3000 Platform 101 ...
Страница 108: ...Figure 94 EX3000S network cabling 108 EX3000 Platform ...
Страница 109: ...Figure 95 EX3000D network cabling EX3000 Platform 109 ...
Страница 112: ...Index E EX500 network cabling 35 ...