Table 39. DC PSU status indicator codes (continued)
Power indicator codes
Condition
same power rating. This results in a PSU mismatch
condition, or failure to power on the system.
CAUTION:
If two PSUs are used, they must be of
the same type and have the same maximum output
power.
CAUTION:
When correcting a PSU mismatch, replace
the PSU with the blinking indicator. Swapping the
PSU to make a matched pair can result in an error
condition and an unexpected system shutdown. To
change from a High Output configuration to a Low
Output configuration or conversely, you must power
off the system.
CAUTION:
Combining AC and DC PSUs is not
supported.
Drive indicator codes
The LEDs on the drive carrier indicate the state of each drive. Each drive carrier has two LEDs: an activity LED (green) and a
status LED (bicolor, green/amber). The activity LED blinks whenever the drive is accessed.
Figure 144. Drive indicators
1. Drive activity LED indicator
2. Drive status LED indicator
3. Drive capacity label
NOTE:
If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on.
NOTE:
Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.
Table 40. Drive indicator codes
Drive status indicator code
Condition
Blinks green twice per second
Indicates that the drive is being identified or preparing for removal.
Off
Indicates that the drive is ready for removal.
NOTE:
The drive status indicator remains off until all drives are
initialized after the system is powered on. Drives are not ready
for removal during this time.
Blinks green, amber, and then powers off
Indicates that there is an unexpected drive failure.
Blinks amber four times per second
Indicates that the drive has failed.
Blinks green slowly
Indicates that the drive is rebuilding.
Solid green
Indicates that the drive is online.
132
System diagnostics and indicator codes