Figure 32. Removing and installing an AC power supply unit
1.
release latch
2. power supply unit cable connector
3. power supply unit
4. connector
5. power supply unit handle
Installing an AC power supply unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Steps
1.
Verify that both the power supply units are the same type and have the same maximum output
power.
NOTE: The maximum output power (shown in watts) is listed on the PSU label.
2.
If applicable, remove the power supply unit blank.
3.
Slide the new power supply unit into the chassis until the power supply unit is fully seated and the
release latch snaps into place.
NOTE: If you unlatched the cable management arm, re-latch it. For information about the cable
management arm, see the system’s rack documentation.
4.
Connect the power cable to the power supply unit and plug the cable into a power outlet.
CAUTION: When connecting the power cable, secure the cable with the strap.
83