3-2
Dell PowerEdge 2200 Systems User’s Guide
Basic Host Adapter Settings
The basic host adapter settings are the SCSISelect set-
tings most likely to require modification.
•
Host Adapter SCSI ID. This option sets the host
adapter’s SCSI ID. The default setting is
SCSI ID 7,
which allows the host adapter to support narrow
SCSI devices in addition to wide SCSI devices. Dell
recommends that you leave the host adapter set to
SCSI ID 7.
•
SCSI Parity Checking. This option determines
whether the host adapter verifies the accuracy of data
transfer on the SCSI bus. The default setting is
Enabled. You should disable SCSI Parity Checking
if any SCSI device connected to the host adapter
does not support SCSI parity; otherwise, leave it
enabled. Most SCSI devices support SCSI parity. If
you are unsure if a device supports SCSI parity, con-
sult the documentation for the device.
•
Host Adapter SCSI Termination. This option sets ter-
mination on the host adapter. The default setting for
all Adaptec 78xx series host adapters is Low On/
High On. Dell recommends that you leave this
option set to the default.
Boot Device Settings
The boot device settings allow you to specify the device
from which to boot your computer.
•
Boot Target ID. This option specifies the SCSI ID of
the device from which you wish to boot your system.
The default setting is SCSI ID 0. The SCSI ID
selected here must correspond to the ID configured
on the boot device.
•
Boot LUN Number. If your boot device has multiple
logical unit numbers (LUNs) and Multiple LUN
Support is enabled (see “Advanced Host Adapter
Settings” found later in this section), this option
allows you to specify a particular LUN from which
to boot on your boot device. The default setting is
LUN 0.
Table 3-1. Default SCSI Controller Settings
Setting
Default
SCSI Bus Interface Definitions:
Host Adapter SCSI ID
7
SCSI Parity Checking
Enabled
Host Adapter SCSI Termination
Low On/High On
Boot Device Options:
Boot Target ID
0
Boot LUN Number
0
SCSI Device/Configuration:
Initiate Sync Negotiation
Yes (Enabled)
Maximum Sync Transfer Rate
40 Mb/sec
Enable Disconnection
Yes (Enabled)
Initiate Wide Negotiation
Yes (Enabled)
Send Start Unit Command
Yes (Enabled)
Advanced Host Adapter:
Host Adapter BIOS
Enabled
Support Removable Disks
Under BIOS as Fixed Disks
Boot Only
Extended BIOS Translation for
DOS Drivers > 1 GB
Enabled
Display <Ctrl><a> Message
During BIOS Initialization
Enabled
Multiple LUN Support
Disabled
BIOS
Support for Bootable
CD-ROM
Enabled
BIOS Support for INT 13
Extensions
Enabled
Support for Ultra SCSI Speed
Enabled
NOTE: For the full name of an abbreviation or acronym
used in this table, see the Glossary.
Содержание Dimension 2200
Страница 1: ... HOO 3RZHU GJH 6 VWHPV 86 5 6 8 ...
Страница 6: ...viii ...
Страница 10: ...xii ...
Страница 22: ...xxiv ...
Страница 30: ...2 4 Dell PowerEdge 2200 Systems User s Guide ...
Страница 64: ...4 18 Dell PowerEdge 2200 Systems User s Guide ...
Страница 88: ...6 8 Dell PowerEdge 2200 Systems User s Guide ...
Страница 100: ...7 12 Dell PowerEdge 2200 Systems User s Guide ...
Страница 118: ...A 4 Dell PowerEdge 2200 Systems User s Guide ...
Страница 128: ...B 10 Dell PowerEdge 2200 Systems User s Guide ...
Страница 140: ...D 6 Dell PowerEdge Systems 2200 User s Guide ...