will occur. When an RTC Reset cycle occurs, the computer turns on and off three times. An "Invalid Configuration" error
message is displayed prompting you to enter the BIOS and configure the date and time. The computer starts functioning
normally after setting the date and time.
NOTE:
Removing the battery resets the BIOS setup program's settings to default. It is recommended that you note the
BIOS setup program's settings before removing the battery.
The following image(s) indicate the location of the battery and provides a visual representation of the removal procedure.
Steps
1. Peel the tape that secures the battery cable to the battery.
2. Ensure that the battery cable has been disconnected from the system board.
3. Remove the six screws (M2x4) that secure the battery to the palm-rest and keyboard assembly.
4. Lift the battery off the palm-rest and keyboard assembly.
Installing the battery
Prerequisites
If you are replacing a component, remove the existing component before performing the installation process.
About this task
The following image(s) indicate the location of the battery and provides a visual representation of the installation procedure.
Removing and installing components
25
Содержание Alienware x17 R1
Страница 1: ...Alienware x17 R1 Service Manual Regulatory Model P48E Regulatory Type P48E001 June 2021 Rev A01 ...
Страница 13: ...Removing and installing components 13 ...
Страница 14: ...14 Removing and installing components ...
Страница 16: ...16 Removing and installing components ...
Страница 45: ...Removing and installing components 45 ...
Страница 53: ...Removing and installing components 53 ...
Страница 56: ...56 Removing and installing components ...