Configuring System Information
105
The following is an example of the PoE CLI commands.
power inline
usage-threshold
Configures the threshold for triggering alarms
power inline
traps enable
Enables PoE device traps
show power inline
[
ethernet
interface
]
Displays PoE configuration information
Console#
show power inline
Power: On
Nominal Power: 150 Watts
Consumed Power: 120 Watts (80%)
Usage Threshold: 95%
Traps: Enabled
Port
Powered Device
State
Priority
Status
Classification [W]
----
--------------
-----
--------
------
------------------
1/e1
IP Phone Model A Auto
High
On
0.44 – 12.95
2/e1
Wireless AP
Model
Auto
Low
On
0.44 – 3.84
3/e1
Auto
Low
Off
N/A
Console#
show power inline ethernet
1/e1
Port
Powered Device
State
Priority
Status
Classification [W]
----
--------------
-----
--------
------
------------------
1/1e
IP Phone Model A Auto
High
On
0.44 – 12.95
Overload Counter: 1
Short Counter: 0
Denied Counter: 0
Absent Counter: 0
Invalid Signature Counter: 0
Table 6-16.
System Health CLI Commands
(continued)
CLI Command
Description
Содержание 48 Port Gigabit Ethernet Switch
Страница 1: ...Dell PowerConnect 34XX Systems User s Guide ...
Страница 48: ...48 Hardware Description w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 78: ...78 Configuring PowerConnect 3424 P and 3448 P w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 233: ...Configuring Switch Information 233 Figure 7 4 Multiple Hosts Table ...
Страница 372: ...372 Viewing Statistics w w w d e l l c o m s u p p o r t d e l l c o m ...
Страница 382: ...382 Configuring Quality of Service w w w d e l l c o m s u p p o r t d e l l c o m ...