Table 19. Dimensions
System
Xa
Xb
Y
Za (with
bezel)
Za (without
bezel)
Zb
*
Zc
4 x 3.5-inches
or
10 x 2.5-inches
482.0 mm
(18.97-inches)
434.0 mm
(17.08-inches)
42.8 mm
(1.68-inches)
35.84 mm
(1.41-inches)
22.0 mm
(0.87-
inches)
733.82 mm
(29.61-inches)
772.67
mm
(30.42-
inches)
8 x 2.5-inches
482.0 mm
(18.97-inches)
434.0 mm
(17.08-inches)
42.8 mm
(1.68-inches)
35.84 mm
(1.41-inches)
22.0 mm
(0.87-
inches)
683.05 mm
(26.89-inches)
721.91
(28.42-
inches)
Chassis weight
Table 20. Chassis weight
System
Maximum weight (with all hard drives/SSDs)
PowerEdge R640
21.9 kg
(48.28 lbs)
Processor specifications
The PowerEdge R640 system supports two Intel Xeon Scalable processors, up to 28 cores per processor.
NOTE:
The sockets for the processors are not hot-pluggable.
Supported operating systems
The Dell EMC PowerEdge R640 supports the following operating systems:
•
Canonical Ubuntu LTS
•
Citrix XenServer
•
Enterprise Linux
•
Microsoft Windows Server with Hyper-V
•
Red Hat Enterprise Linux
•
SUSE Linux Enterprise Server
•
VMware ESXi
NOTE:
For more information, go to
Cooling fan specifications
The cooling fans are integrated into the system to dissipate the heat generated by the functioning of the system. These fans provide
cooling for the processors, expansion cards, and memory modules.
Your system supports up to eight standard or high performance cooling fans.
NOTE:
• High performance fans can be identified by a blue label on top of the cooling fan.
• Mixing of standard and high performance cooling fans is not supported.
• Each fan is listed in the systems management software, referenced by the respective fan number. If there is a
problem with a particular fan, you can easily identify and replace the proper fan by noting the fan number on the
system.
32
Technical specifications