4. Gently push down on the upper-left circle on the 4-port card.
5. Push up on the blue tabs until they lock into place.
Figure 48 Locking the 4-port card into position
6. Install the air dam that came with the 4-port card, and tighten the four captive
screws.
7. If the 4-port card includes SFPs, install them into the embedded module.
Install an embedded module
Procedure
1. Align the embedded module with the empty slot and carefully push it into the
slot.
As the embedded module is installed, the release lever rotates inward.
Figure 49 Installing the embedded module
2. When the embedded module is fully seated, push the release lever back into the
system until the orange tab locks the lever in place.
Service Procedures
Install an embedded module
59