ReadyRail mounting brackets for rack installation, included
•
Screws for rack installation, not included
•
#1 and #2 Phillips screw drivers, not included
•
Torx screwdriver, not included
•
Ground cable screws for L-bracket, included
•
Copper/fiber cables
•
S5296F-ON: USB male–female extension cable
Other optional components are:
•
Ground cable and lug for the frame-end of the ground cable
•
Extra mounting brackets
•
Extra power supply unit
•
Extra fan module
NOTE:
The DC ground lug kit ships with the other accessories inside the shipping box.
S5200F-ON Series switch configurations
You can order the S5200F-ON Series switch in several different configurations.
•
S5200F-ON Series AC or DC Normal Airflow switch:
– S5232F-ON—one RU, 32 x 100GbE ports, two AC or DC power supplies, and four fan subsystems with airflow from the I/O side to
the power supply side
– S5248F-ON— one RU, 48 x 25GbE ports, 4 x 200GbE ports, 2 x 200GbE QSFP-DD ports, two AC or DC power supplies, and four
fan subsystems with airflow from the I/O side to the power supply side
– S5296F-ON— two RU, 96 x 25GbE ports and 8 x 100GbE ports, two AC or DC power supplies, four fan subsystems with airflow
from the I/O side to the power supply side, and one USB male–female extension cable
•
S5200F-ON Series AC or DC Reverse Airflow switch:
– S5232F-ON—one RU, 32 x 100GbE ports, two AC or DC power supplies, and four fan subsystems with airflow from the power
supply side to the I/O
– S5248F-ON— one RU, 48 x 25GbE ports, 4 x 200GbE ports, 2 x 200GbE QSFP-DD ports, two AC or DC power supplies, and four
fan subsystems with airflow from the power supply side to the I/O
– S5296F-ON— two RU, 96 x 25GbE ports and 8 x 100GbE ports, two AC or DC power supplies, four fan subsystems with airflow
from the power supply side to the I/O, and one USB male–female extension cable
•
Fan with airflow from the I/O side to the PSU side—normal airflow
•
Fan with airflow from the PSU side to the I/O side—reverse airflow
•
AC or DC power supply with airflow from the I/O side to the PSU side—normal airflow
•
AC or DC power supply with airflow from the PSU side to the I/O side—reverse airflow
Luggage tag
The switch has a pull-out tag, known as a luggage tag, on the PSU-side of the switch. The front of the luggage tag includes switch ID
information. The back of the luggage tag includes a QRL that takes you to a How-To site where you can watch videos about racking the
switch, replacing components, configuring port channels, and so on.
S5200F-ON Series switch
17