Safety features:
•
To prevent the rack from tipping, slide only one enclosure out of the rack at a time.
•
The drawer locks into place when fully opened and extended. To reduce finger pinching hazards, two latches must be released before
the drawer can be pushed back into the drawer slot within the enclosure.
Each drawer can be locked shut by turning both anti-tamper locks clockwise using a screwdriver with a Torx T20 bit (included in your
shipment). The anti-tamper locks are symmetrically placed on the left and right sides of the drawer bezel. Drawer status and activity LEDs
can be monitored by two drawer LEDs panels located next to the two drawer-pull pockets located on the left and right side of each drawer.
Figure 27. Drawer bezel details
1
Left side
2
Right side
3
Anti-tamper lock
4
Sideplane OK/Power Good
5
Drawer fault
6
Logical fault
7
Cable fault
8
Drawer activity
9
Drawer pull handle
NOTE:
This figure shows symmetrical drawer bezel details. The callouts provided on the right side detail also pertain to the left
side detail. For descriptions of drawer LED behavior, see
Table 18. Drawer LED descriptions
Operator's (Ops) panel LEDs
Each ME4 Series enclosure features an Ops panel located on the chassis left ear flange. This section describes the Ops panel for 2U and
5U enclosures.
2U enclosure Ops panel
A flexible cable connects the Ops panel to the midplane. The Ops panel is a passive component: the midplane controls the panel, and the
IOMs control all the panel’s functions. An integral part of the enclosure chassis, the Ops panel is not replaceable on site. The Ops panel
provides the functions shown in the illustration below and listed in
Table 4. Ops panel functions (see left ear on 2U front panel)
.
22
Storage system hardware
Содержание PowerVault ME484