Uninstall OS—Deletes the contents of all disk partitions, including the NOS configuration, except ONIE and diagnostics.
•
Update ONIE—Installs a new ONIE version.
•
Embed ONIE—Formats the disk and installs ONIE.
•
EDA DIAG—Runs the system diagnostics.
After the ONIE process installs an NOS image and you later reboot the switch in
ONIE: Install OS
mode (default), ONIE takes
ownership of the system and remains in Install mode (ONIE Install mode is sticky) until an NOS image successfully installs again. To boot
the switch from ONIE for any reason other than installation, select the
ONIE: Rescue
or
ONIE: Update ONIE
option from the ONIE
boot menu.
CAUTION:
During an automatic or manual NOS installation, if an error condition occurs that results in an unsuccessful
installation and if there is an existing OS on the device, select
Uninstall OS
to clear the partitions. If the problem
persists, contact Dell EMC Technical Support.
Automatic NOS installation
You can automatically install an NOS image on a Dell EMC ONIE-enabled device. This process is known as zero-touch install. After the
device boots to
ONIE: Install OS
, ONIE autodiscovery follows these steps to locate the installer file and uses the first successful
method:
1. Use a statically configured path that is passed from the boot loader.
2. Search file systems on locally attached devices, such as USB.
3. Search the exact URLs from a DHCPv4 server.
4. Search the inexact URLs based on the DHCP responses.
5. Search IPv6 neighbors.
6. Start a TFTP waterfall.
The ONIE automatic discovery process locates the stored software image, downloads, and installs it, and reboots the device with the new
image. Autodiscovery repeats until a successful software image installation occurs and reboots the switch.
ONIE discovery — Usage information
•
All ONIE autodiscovery methods download and run only supported default file names, such as
onie-installer
. The required file
names and search order are described on the Open Network Install Environment website at
. For more
information, see the
Open Networking Hardware Diagnostic Guide
•
If you use a DHCPv4 server, ONIE autodiscovery obtains the hostname, domain name, Management interface IP address, and the IP
address of the domain name server (DNS) from the DHCP server and DHCP options. It also searches SCP, FTP, or TFTP servers with
the default DNS of the ONIE server. DHCP options are not used to provide the server IP.
•
If you use a USB storage device, ONIE searches only FAT or EXT2 file systems for an NOS image.
Example: NOS automatic installation
1. On the TFTP server, rename the NOS image to a supported installer file name, such as
onie-installer
, using the
mv
image-
name default-filename
command.
mv
<NOS-image-name>
.bin onie-installer
2. Boot up the switch in
ONIE: Install
mode to install an NOS image.
Starting: discover... done.
ONIE:/ # Info: eth0: Checking link... up.
Info: Trying DHCPv4 on interface: eth0
ONIE: Using DHCPv4 addr: eth0: xx.xx.xx.xx / xxx.x.x.x
Info: eth1: Checking link... down.
ONIE: eth1: link down. Skipping configuration.
ONIE: Failed to configure eth1 interface
ONIE: Starting ONIE Service Discovery
Info: Fetching tftp://xx.xx.xx.x/onie-installer-x86_64-dellemc_
<platform>
_c2338 ...
Info: Fetching tftp://xx.xx.xx.x/onie-installer-dellemc_
<platform>
_c2338 ...
Info: Fetching tftp://xx.xx.xx.x/onie-installer-x86_64-bcm ...
Info: Fetching tftp://xx.xx.xx.x/onie-installer-x86_64 ...
Info: Fetching tftp://xx.xx.xx.x/onie-installer ...
ONIE: Executing installer: tftp://xx.xx.xx.x/onie-installer
...
...
...
52
Installation using ONIE
Содержание PowerSwitch N2200-ON Series
Страница 1: ...Dell EMC PowerSwitch N2200 ON Series Installation Guide...
Страница 16: ...1 Product ID QRL 2 Product information QRL 3 SVC tag 4 MAC address 5 Exp Svc code 16 N2200 ON Series switch...
Страница 44: ...1 Fan N2224X ON fan installation 1 Fan N2248PX ON fan installation 1 Fan N2248X ON fan installation 44 Fans...