Dell EMC PowerStore
Hardware Information Guide
Страница 1: ...Dell EMC PowerStore Hardware Information Guide ...
Страница 2: ...amage to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death 2020 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners May 2020 Rev A00 ...
Страница 3: ...ase enclosure power supply 12 Node internal components 13 3 Expansion enclosure component descriptions 14 2U 25 drive expansion enclosure 14 2U 25 drive expansion enclosure front view 14 2U 25 drive expansion enclosure rear view 15 4 Technical specifications 18 Physical specifications 18 Dimensions and weight 18 Power requirements 19 Operating limits 20 Shipping and storage requirements 20 Base en...
Страница 4: ... licensing information can be obtained as follows Product information For product and feature documentation or release notes go to the PowerStore Documentation page at www dell com powerstoredocs Troubleshooting For information about products software updates licensing and service go to www dell com support and locate the appropriate product support page Technical support For technical support and...
Страница 5: ... software stack is deployed on the hypervisor and the hypervisor enables deployment of VMs and applications within the PowerStore hardware PowerStore hardware consists of a 2U two node storage solution The enclosure as a whole is called a base enclosure Between the front and rear of the enclosure a mid plane distributes power and signals to all the enclosure components On the front of the base enc...
Страница 6: ...use two NVMe NVRAM drives slots 21 and 22 must remain empty NOTE A minimum of six NVMe SSD or NVMe SCM drives and two or four NVMe NVRAM drives depending on the model must be installed in the base enclosure If the minimum number of drives is not populated the base enclosure will not initialize NOTE You cannot add additional NVMe NVRAM drives to models that ship with two WARNING NVMe NVRAM drives a...
Страница 7: ...closure front view The front of the base enclosure contains the following elements Figure 1 Base enclosure front view Table 1 Base enclosure component locations Location Description SSD or SCM NVMe drives NVRAM NVMe drives NOTE In configurations that only use two NVMe NVRAM drives slots 21 and 22 must remain empty Base enclosure power on LED Drive power and activity LED Drive fault LED Figure 2 Ba...
Страница 8: ...els for tracking hardware components Service Tag The Service Tag for the 25 slot base enclosure is a black pull out tag that is located between the drives in slots 16 and 17 Figure 3 Service Tag location World Wide Name Seed Tag The World Wide Name WWN Seed Tag is a blue pull out tag that is located between the drives in slots 7 and 8 Figure 4 WWN Seed Tag location Base enclosure rear view The rea...
Страница 9: ...ween nodes and appliances The first two ports of the 4 port card on the embedded module connect to a 10GbE 25GbE Ethernet switch NOTE Both nodes must have the same type of embedded modules in the same slots The embedded module contains the following components One 4 port card One non maskable interrupt NMI button Two mini SAS HD back end ports Two RJ 45 LAN connectors System management port Servic...
Страница 10: ...pported 4 port cards the 4 port 25GbE SFP based embedded module and the 4 port 10GBaseT embedded module The 4 port 25GbE SFP based embedded module supports 1GbE SFP to RJ45 10GbE or 25GbE SFP28 25GbE passive TwinAx and 10GbE active or passive TwinAx Depending on the installed SFP or TwinAx cable the following speeds are supported 1GbE 10GbE and 25GbE The ports may be configured individually with T...
Страница 11: ...wer Green Node is on main power Green blinking Node is initializing a serial over LAN session Standby Mode Off Node is off Unsafe to remove White Do not remove the node Improper removal could cause data loss Off Safe to remove the embedded module when the embedded module has been properly prepared Base enclosure I O module types 4 port 25GbE SFP based I O module The 4 port 25GbE SFP based I O modu...
Страница 12: ... LED Location State Description Port link Green or blue Link up Off Link down Power fault Green Power on Amber Power fault Port labels in PowerStore Manager In PowerStore Manager on the Hardware Rear View tab for an appliance the following port abbreviations are used FEPort Physical Frontend Port hFEPort Hypervisor Frontend Port vFEPort Virtual Frontend Port Base enclosure power supply Figure 9 Ba...
Страница 13: ...Li ion internal battery that powers the associated NVRAM cache drives during a power event Internal M 2 boot module Each node has two internal M 2 boot modules on an M 2 boot module adaptor located between DIMM slots 11 and 12 One internal M 2 boot module is used for general system operations and the other internal M 2 boot module is used for recovery Fan module Seven redundant fan modules connect...
Страница 14: ...nclosure front view Table 8 2U 25 drive expansion enclosure component locations Location Description 1 2 5 inch 12 Gb s SAS drives 2 Expansion enclosure fault LED amber 3 Expansion enclosure power status LED blue 4 Drive status and activity blue 5 Drive fault LED amber Table 9 2U 25 drive expansion enclosure and drive status LEDs LED Location Color State Description Expansion enclosure fault 2 Blu...
Страница 15: ...s connect the LCCs in a system in a daisy chain topology Internally each expansion enclosure LCC uses protocols to emulate a loop The LCC connects to the drives in its enclosure in a point to point fashion through an internal switch The LCC independently receives and electrically terminates incoming signals For traffic from the node the LCC switch passes the signal from the input port to the drive...
Страница 16: ...e On SAS port linked up Off No connector in port 2U 25 drive expansion enclosure power supply and cooling module Power supply and cooling module functions and features The power supply and cooling modules are located to the left and right of the LCCs The units integrate independent power supply and two dual blower cooling assemblies into a single module Each power supply is an auto ranging power f...
Страница 17: ...ot supported 4 Power supply and cooling module fault LED 5 Grounding screw 6 Power supply AC power in recessed plug Table 13 2U 25 drive expansion enclosure AC power supply and cooling module LED status LED Location Color State Description AC power LED input 2 Green On AC power on Off AC power off verify source power DC power LED output 3 Green On DC power on not supported Off DC power off verify ...
Страница 18: ...B Embedded SAS I O ports 4 x 4 lane 12 Gb s SAS ports for back end connection Dimensions and weight Base enclosure Table 15 2U 25 drive base enclosure dimensions and weight Dimension Value Weight fully populated 41 7 kg 92 lbs Vertical size 2 NEMA units Height 8 64 cm 3 4 in Width 44 45 cm 17 5 in Depth 79 5 cm 31 3 in NOTE The weight does not include mounting rails Allow 3 6 kg 8 lbs for a rail s...
Страница 19: ... J hr 5 995 Btu hr 6 32 x 106 J hr 5 995 Btu hr 6 59 x 106 J hr 6 248 Btu hr 7 37 x 106 J hr 6 985 Btu hr AC Inlet type IEC320 C14 or IEC320 C20 appliance coupler per power zone IEC320 C20 appliance coupler per power zone Normal input frequency 47 Hz 63 Hz Maximum inrush current 45 Apk cold per line cord at any line voltage AC protection 20 A fuse on each power supply single line Ride through time...
Страница 20: ...cutive months of unpowered storage Base enclosure airflow The base enclosure uses an adaptive cooling algorithm that increases or decreases fan speed as the unit senses changes to the external ambient temperature Exhaust increases with ambient temperature and fan speed and is roughly linear within recommended operating parameters Note that the information in the table below is typical and was meas...
Страница 21: ...rate of the coupons should be less than 300 Angstroms When monitored reactivity rate is exceeded the coupon should be analyzed for material species and a corrective mitigation process put in place Storage time unpowered recommendation do not exceed 6 consecutive months of unpowered storage Fire suppressant disclaimer Fire prevention equipment in the computer room should always be installed as an a...
Страница 22: ...Packaged system condition Response measurement level Transportation shock 10 G s 12ms duration Transportation random vibration 1 15 Grms 1 hour Frequency range 1 200 Hz 22 Technical specifications ...