Table 35. Library page settings (continued)
Item
Description
●
DDVTL
Starting Barcode
Enter the desired barcode for the first tape, in the format A990000LA.
Tape Capacity
(Optional) Enter the tape capacity. If not specified, the capacity is derived from the last
character of the barcode.
VTL Protocol Access Group page
The Access Group page enables you to configure DD VTL protocol settings for an access group.
To configure these settings outside of the configuration wizard, select
PROTOCOLS
>
VTL
>
Access Groups
>
Groups
>
More Tasks
>
Group
>
Create
.
Table 36. Access Group page settings
Item
Description
Group Name
Enter a unique name of from 1 - 128 characters. Duplicate access groups are not supported.
Initiators
Select one or more initiators. Optionally, replace the initiator name by entering a new one. An
initiator is a backup client that connects to a system to read and write data using the Fibre
Channel (FC) protocol. A specific initiator can support DD Boost over FC or DD VTL, but not
both.
Devices
The devices (drives and changer) to be used are listed. These are available on all endpoints. An
endpoint is the logical target on the protection system to which the initiator connects.
Selecting and configuring Secure Remote Services
delivery
Secure Remote Services Virtual Edition (VE) Gateway provides automated connect home and remote support activities through
an IP-based solution that is enhanced by a comprehensive security system.
About this task
An on-site Secure Remote Services version 3 gateway provides the ability to monitor both on-site protection systems and DDVE
instances, and cloud-based DDVE instances.
Steps
1. Select
Maintenance
>
Support
>
Autosupport
.
2. Click
Configure
in the Channel row in the Support area.
The Configure Dell EMC Support Delivery dialog box appears. The delivery method is displayed after the Channel label in the
Support area.
3. In the
Channel
list box, select
Secure Remote Services
.
4. Type the gateway hostname, and select the local IP address for the system.
5. Click
OK
.
6. Type the service link username and password.
7. Click
Register
.
Secure Remote Services details are displayed in the Autosupport panel.
8. To test ConnectEMC operation, use the CLI.
#support connectemc test
Sending test message through ConnectEMC...
Test message successfully sent through ConnectEMC.
Configure System for Use
81
Содержание PowerProtect DD9400
Страница 1: ...Dell EMC PowerProtect DD9400 System Installation Guide September 2020 Rev 03...
Страница 57: ...Figure 65 Single node DD9400 with DS60 shelves Connect Cables and Power On 57...
Страница 58: ...Figure 66 HA DD9400 with DS60 shelves 58 Connect Cables and Power On...
Страница 63: ...Figure 72 Routing cables through the CMA brackets Connect Cables and Power On 63...