![Dell EMC PowerEdge T440 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/dell-emc/poweredge-t440/poweredge-t440_installation-and-service-manual_2468323034.webp)
Table 21. Maximum shock specifications
Maximum shock
Specifications
Operating
Six consecutively executed shock pulses in the positive and negative x, y,
and z axes of 6 G for up to 11 ms.
Storage
6 consecutively executed shock pulses in the positive and negative x, y, and
z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 22. Maximum altitude specifications
Maximum altitude
Specifications
Operating
3048 m (10,000 ft)
Storage
12,000 m (39,370 ft)
Table 23. Operating temperature derating specifications
Operating temperature derating
Specifications
Up to 35°C (95°F)
Maximum temperature reduces by 1°C/300 m (1°F/547 ft) above 950 m
(3,117 ft).
35 °C–40°C (95 °F–104°F)
Maximum temperature reduces by 1°C/175 m (1°F/319 ft) above 950 m
(3,117 ft).
40 °C–45°C (104 °F–113°F)
Maximum temperature reduces by 1°C/125 m (1°F/228 ft) above 950 m
(3,117 ft).
Standard operating temperature
Table 24. Standard operating temperature specifications
Standard operating temperature
Specifications
Continuous operation (for altitude less than 950 m or 3117
ft)
10°C–35°C (50°F–95°F) with no direct sunlight on the equipment.
Expanded operating temperature
Table 25. Expanded operating temperature specifications
Expanded operating
temperature
Specifications
Continuous operation
5°C–40°C at 5% to 85% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C–35°C), the system can operate
continuously in temperatures as low as 5°C and as high as 40°C.
34