Verify the chassis replacement
Procedure
1. Run the
disk rescan
command to discover the disks.
a. If all of the disks are not listed, perform another rescan.
b. If all of the disks are still not listed, check the connection.
2. Enter the
alerts show current
command and confirm that the system has no alerts.
#
alerts show current
No active alerts.
Note:
If the command output displays hardware failure, use the appropriate sections in
this document (PSU, controller, disk, and fan) to identify and verify the component
connections until there are no alerts.
Bezel Replacement
This section describes how to install or remove a bezel.
Unlocking and removing the front bezel
About this task
NOTICE
You must remove the enclosure’s front bezel to gain access to the disks. The bezel is
required for EMI compliance when the enclosure is powered up. Remove it only to replace or
add a disk.
Procedure
1. Insert the key that shipped with your enclosure into the bezel lock, and turn it to release the
lock.
2. Press the two latch buttons on the bezel surface to release the bezel from the cabinet
(
Removing and replacing FRUs
Dell EMC ES40 Expansion Shelf Guide Field Replacement Unit Guide
53