2. Click on the failed node and select Manage
>
Settings
>
General.
3. In the Add disks to storage list box, select Manual.
Disconnect power cords and I/O cables
This procedure is used to disconnect the power cords and I/O cables from the server.
Procedure
1. Label each cord and cable so you can easily identify them when you need to
plug them into the replacement server.
2. Unplug power cords from the power supplies and disconnect I/O cables from
the server.
Remove the server from the cabinet (sliding rails)
This procedure is used to remove the server (mounted on sliding rails) from the
cabinet for replacement of a faulted server.
CAUTION
The server is heavy and should be removed from a cabinet by two people. To
avoid personal injury and/or damage to the equipment, do not attempt to remove
the server from a cabinet without a mechanical lift and/or help from another
person.
The disk drives from the faulted server will be transferred to the replacement server.
You will need suitable work surface(s), capable of supporting the weight of the servers
while the transfer is accomplished.
Procedure
1. At front of the cabinet, locate the slam latch on either side of the server (1).
Pull up the slam latches to release the server from the cabinet (2). Then, pull
the server from cabinet until the rails lock in place.