Figure 67. Cable routing - 4 x 3.5-inch SAS backplane with PERC
Power supply unit
NOTE:
For more information, see the
section.
Hot spare feature
Your system supports the hot spare feature that significantly reduces the power overhead associated with power supply unit (PSU)
redundancy.
When the hot spare feature is enabled, one of the redundant PSUs is switched to the sleep state. The active PSU supports 100 percent of
the load, thus operating at higher efficiency. The PSU in the sleep state monitors output voltage of the active PSU. If the output voltage of
the active PSU drops, the PSU in the sleep state returns to an active output state.
If having both PSUs active is more efficient than having one PSU in the sleep state, the active PSU can also activate the sleeping PSU.
The default PSU settings are as follows:
•
If the load on the active PSU is more than 50 percent, then the redundant PSU is switched to the active state.
•
If the load on the active PSU falls below 20 percent, then the redundant PSU is switched to the sleep state.
You can configure the hot spare feature by using the iDRAC settings. For more information about iDRAC settings, see the
Integrated Dell
Remote Access Controller User’s Guide
available at
Dell.com/idracmanuals
.
Removing a power supply unit blank
Prerequisite
1
Follow the safety guidelines listed in
Step
Pull the blank out of the system.
Installing and removing system components
91