Industrial vacuum
TP.CV-070
Operator’s and maintenance manual
Original and official manual
Read this manual carefully before using the vacuum cleaner
Страница 1: ...Industrial vacuum TP CV 070 Operator s and maintenance manual Original and official manual Read this manual carefully before using the vacuum cleaner ...
Страница 2: ...fidential nature Even partial reproduction of the graphic project the text and the illustrations are legally forbidden Some details shown in the illustrations in this manual may be different from those of your vacuum cleaner Some component parts may have been removed for greater clarity For easier reference this manual is split into sections identifiable by specific graphic symbols The subjects de...
Страница 3: ...Introduction 2018 ...
Страница 4: ...tails 5 1 11 Warranty 6 Safety section 2 1 Safety details 7 2 2 Safety warnings 8 2 3 Safety plates and symbols 11 2 4 Outstanding risks 12 2 5 Applied directives Installation section 3 1 Handling 13 3 2 Installation 14 Operation section 4 1 Description of controls 16 4 2 Work cycle 17 Maintenance section 5 1 Informative notes 19 5 2 General safety warnings 5 3 Maintenance operations 20 5 4 Troubl...
Страница 5: ...Information Section 1 1 Identification of main parts 1 2 4 1 Switchboard 3 2 Castors 3 Wheels 4 Suction unit 5 Inlet for TP CV connection ...
Страница 6: ...Information Section 1 2 Accessories provided FI 0164 0000 HEPA SAFETY FILTER ONLY SPARE PART ...
Страница 7: ...Italy Tel 0039 011 800 55 00 Fax 0039 011 800 55 06 www delfinvacuums it delfin delfinvacuums it 1 4 Marking plate In compliance with the Machine Directive 2006 42 CE on vacuum cleaners the machine is fitted with CE plates When contacting the manufacturer or dealer always quote the details shown on the vacuum cleaner plate ...
Страница 8: ...been taken from a distance of 1 meter and from a height of 1 60 meters showing an acoustic pressure no higher than 69 dB A The vibrations transmitted by the machine are lower than 2 5 m2 s Attention Pursuant to articles L D 81 08 workers exposed to sound pressure levels above 85 dB A must be protected by special individual protection devices It is therefore necessary if such working conditions exi...
Страница 9: ... Technical details TP CV 070 Power kW 3 0 Voltage Volts 415 Max vacuums rate mm H2O 2 700 Max air flow rate m3 h 318 Noise level dB A 69 Filter type Absolute filter H Capacity lt Suction inlet Ø 60 Dimensions cm 67 X 58 X 110 ...
Страница 10: ...ny cleaning of working parts Faults not directly attributable to materials or manufacture shall be examined only in our facility or in a Technical Assistance Centre indicated by us If claims appear unjustified all the costs relating to repair and or replacement of parts shall be charged to the buyer The purchase tax document shall be shown to the technical personnel making the repairs and must acc...
Страница 11: ...l as by even partial failure to comply with the safety regulations and intervention procedures indicated in this manual The safety Warnings and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the operator could become involved in accidents with serious consequences for him herself and for other people The safety messages are highlighted by th...
Страница 12: ...ust be explicitly requested by you If the machine is used to vacuum toxic harmful substances the container must be emptied and the filters cleaned using adequate individual protection devices selected according to the type of substances to be vacuumed Do not vacuum flammable materials or substances or which could cause explosions fuels solvents etc To vacuum such materials the machine must be buil...
Страница 13: ...verhaul to DELFIN U R L The machine is supplied with instruction manual Exploded Spare Parts drawing Test Sheet Warranty Slip Approval Certificate In the event of Customers fitting a tool to the machine not supplied by DELFIN make sure the safety conditions required by Machine Directive 2006 42 CE are complied with and in any event DELFIN is unable to accept liability for any problems arising from...
Страница 14: ...g MACHINE BEING SERVICED DO NOT START Climbing on the cleaner is forbidden Never touch electric wires switches buttons etc with wet hands Before connecting to the power mains make sure the power voltage and frequency are those shown on the machine plate Make power connections to a mains supply with efficient earth system In the event of an extension being used make sure this is in perfect conditio...
Страница 15: ...ages are legible Clean these with a cloth soap and water Do not use solvents diesel fuel or petrol Replace the damaged plates with new ones supplied by Delfin If a plate is affixed to a replaced part make sure a new plate is affixed to the new part Attention Read the operator s and maintenance manual carefully before using the cleaner or doing any maintenance jobs ...
Страница 16: ...leaner must not be used in environments containing substances in the form of liquids that could vaporize at room temperature and flammable dusts and gas Risks of operation in humid environments Keep to the limits shown in this manual at chap 1 6 Allowed environmental conditions Risk of erroneous interpretation of the safety pictograms Having identified the various outstanding risks the manufacture...
Страница 17: ...ng objects on the packaging During movement keep the load low for greater stability and safety When starting up the vacuum cleaner move this by means of the wheels supplied The appliance must never be moved using fork lift trucks or other equipment that lifts it off the floor If for any reason the need arises to lift and transport the vacuum cleaner this operation must be performed under the respo...
Страница 18: ...er and reach an agreement on how to proceed The vacuum cleaner already features a suction filter Fit the accessory required for the type of vacuuming operation on the opposite end of the hose Note No standard accessories reducers hoses nozzles are included with the vacuum accessories must be specified and ordered separately Contact your dealer for information relating to the different types of opt...
Страница 19: ...the vacuum cleaner plate TP CV 070 190308274 2019 Warning Do not fit the plug in the power socket with wet hands In the event of an extension being used make sure this is in perfect condition in compliance with CE standards and with cable cross section suitable for the power input of the vacuum cleaner ...
Страница 20: ...LIGHT 3 THERMAL RELEASE YELLOW LIGHT 4 FILTER CLEANING GREEN LIGHT 5 FILTER CLEANING MODE AUTO MAN SEP 6 SUCTION START MODE 7 START SUCTION CV FILTER CLEANING SEP MANUAL MODE GREEN BUTTON 8 SUCTION ON GREEN LIGHT 9 STOP SUCTION RESET RED BUTTON 10 DISCHARGE CYCLE GREEN LIGHT 11 DISCHARGE FAULT RED LIGHT ...
Страница 21: ...tton Warning Before switching the vacuum cleaner back on make sure the motors have come to a complete halt After finishing work disconnect the vacuum cleaner from the power socket System parameters T1 suction time when this time ends the machine will make a discharging cycle the solenoid valve EV1 is excited and after 1 second the solenoid valve EV2 is excited too T2 discharging time when this tim...
Страница 22: ...again a check of the position of the discharging flap has to be performed When T2 time ends then the checking time T3 begins Only when T3 ends the magnetic proximity sensor checks that the discharging flap is closed If the flap is closed after T1 time the cycle begins again If after T3 time the flap is not closed the engine stops and the discharging fault light indicator turns ON Pushing the reset...
Страница 23: ...determining the professional capacities and skills of such persons Before doing any maintenance job the safety manager must Make sure there are no unauthorized persons in the work area Make sure the necessary tools are on hand and that these are in good condition Make sure that lighting is adequate and if necessary provide 24 V portable lamps Make sure the maintenance engineer is equipped with all...
Страница 24: ...e filter holder ring and of the container are working efficiently The electrical parts plugs switches cables etc must not be faulty The screws and nuts must always be tight Check the integrity of the flexible vacuum hose and accessories to be used If the flexible hose is perforated the power of the cleaner will be reduced and dust and liquids will leak into the environment A qualified operator mus...
Страница 25: ...pe of job Fit a suitable filter for the type of material to be vacuumed Pipe perforated or blocked Container full Check the pipe and if necessary replace it Empty container The vacuum cleaner does not work as it should Filter blocked Seals worn Air leak Clean the filter and if necessary change it Check the seals and if necessary replace it Check for any air leaks out of closing fasteners tightenin...
Страница 26: ...Spare Parts Section 6 1 Recommended spare parts Code Description FI 0164 0000 HEPA SAFETY FILTER ...
Страница 27: ...Spare Parts Section Delfin Syl Strada Della Merle 49 a 10036 SiTime Tories TO Italy Tel 0039 011 8005500 Fax 0039 011 8005506 ...