8.2.4
Maintenance of the festoon system
CAUTION!
-
Turn off the power supply and ensure that no inadvertent activation is possible.
-
When installation tasks are carried out above eye level, use proper climbing aids and working
platforms.
-
Do not use machine components as climbing aids.
-
Ensure that process and auxiliary materials are drained, collected and disposed of in a safe and
environmentally friendly manner.
-
Safety devices that were removed for installation, service or repair must be immediately remounted
and inspected after work is completed.
-
Observe the inspection and maintenance intervals described in the maintenance instructions.
-
Ensure that sufficient space for maintenance work is available.
-
Ensure that the festoon system is not inadvertently activated during maintenance work.
-
Ensure that detached parts do not fall.
-
Screw joints that were loosened during maintenance work must be retightened and secured
according to instructions.
-
Fasteners and seals that cannot be reused are to be replaced (such as self-locking nuts, disks,
splints, O-rings, glued or microencapsulated screws).
-
Lubrication/greasing points that are cleaned or wiped during maintenance and repair work must be
relubricated as instructed.
-
After finishing work, collect all tools and materials and check that all are present.
-
Disassembled parts and components that were exchanged are to be collected, stored in a safe
place, recycled or sent back.