Dekolink Deko3108S Скачать руководство пользователя страница 1

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
© Dekolink Wireless Ltd.—All Rights Reserved 

 

 

       Rev. 

B

 

 

 

Содержание Deko3108S

Страница 1: ...Dekolink Wireless Ltd All Rights Reserved Rev B...

Страница 2: ......

Страница 3: ...eless channels or customers The material herein is proprietary to Dekolink Wireless Ltd Any unauthorized reproduction use or disclosure of any part thereof is strictly prohibited All trademarks and re...

Страница 4: ...nd maintenance of this product Only a qualified and authorized personnel should carry out adjustment maintenance or repairs to the components of this equipment DANGER ELECTRICAL SHOCK This equipment i...

Страница 5: ...NTS Select a power supply cord that is UL listed or CSA Certified 3 Conductor 18AWG SJT with a length between 1 5m and 4 5m terminated in a molded on plug cap rated 250V 15A and matching connector wit...

Страница 6: ...LESS LTD Page iv Proprietary Data P N 300XC10031 Rev B REVISION HISTORY The revision history for this document is shown in Table 1 Table 1 Revision history P N Revision Date Description 300XC10031 A 0...

Страница 7: ...ion Requirements 13 2 1 Power Requirements 13 2 2 Grounding Wires Requirements 13 2 3 Antenna Requirements 13 2 4 Pre Installation Safety Instructions 14 2 5 Installation Location Environment and Cabl...

Страница 8: ...r Interface 37 5 2 Repeater Network and Communication Parameters 39 5 3 Monitoring Alarms and Troubleshooting 40 5 4 Deko CMU Alarms Log 42 5 5 Viewing Repeater Information 43 6 ADMINISTRATION 45 6 1...

Страница 9: ...he actual range of RSSI levels over a user specified period of time The SmartALC algorithm prevents oscillations reduces the amount of isolation required by the system and optimizes the system to mini...

Страница 10: ...nuator VVA that whenever a high input signal is received attenuates the signal level so that the output power of the amplifier does not exceed the preset limit 1 3 2 SALC Description The Smart Automat...

Страница 11: ...atically reduces the gain in accordance with the new isolation conditions Once the isolation problem is solved the repeater automatically raises the gain again This operation is remotely monitored and...

Страница 12: ...cated on the underside of the Repeater as illustrated below Figure 1 2 Deko3108S Front Panel The following table provides a description of the front panel ports and connections Group Connectors BASE D...

Страница 13: ...rnal Power Selector for service personnel The Max Gain is factory set to its minimum value by default The RF power level can be modified either through the GUI default 4 3 or through the internal sele...

Страница 14: ...r antenna Figure 1 4 Connections Unit Power Selector and Indicators LED Colors Refer to Appendix B Troubleshooting for detailed information on each LED indicator Color Description Green Normal operati...

Страница 15: ...section 10AWG Lug of the protective grounding conductor should be aluminum Washers and screw should be high Cr stainless steel or 12 Cr stainless steel or Cr on Ni on steel tin on steel 2 3 ANTENNA R...

Страница 16: ...the Repeater During normal operation the Repeater door should be closed Some maintenance tasks may require the iDEN midi repeater door to be opened while the power is on In such cases perform the req...

Страница 17: ...gure provides an overview of the Deko3108S connections 3 2 UNPACKING Upon receiving the Deko3108S unit perform the following 1 Examine the shipping container for damage before unpacking the unit 2 Per...

Страница 18: ...for brick wall installation See 3 4 2 1 3 4 MOUNTING THE DEKO3108S 3 4 1 Pre Mounting Procedure NOTE The weight of the unit requires that two people mount the unit on the wall 1 Choose the location of...

Страница 19: ...DEKOLINK WIRELESS LTD DEKO3108S MIDI REPEATER PRODUCT MANUAL P N 300XC10031 Rev B Proprietary Data Page 17 Figure 2 Mounting Fixture Measurements...

Страница 20: ...Plated Steel Anchor Bolt With Integrated Washer such as FUR 8x80 Fischer Fixing Systems or compatible from other companies See 3 4 2 2 Plywood and Gypsum Drywall Anchor Hexagon Head Screws Install at...

Страница 21: ...ors to secure the support Mounting Fixture firmly to the wall Insert the anchors and using a hammer tap the part being fastened into the drilled hole until the washer is in contact with the fastened p...

Страница 22: ...er Construction Members located under the Gypsum Drywall The following figure provides a description of the installation of the anchors in the plywood plate Use anchor hexagon head screws to secure th...

Страница 23: ...21 Figure 3 4 Hanging Repeater on Mounting Fixture Figure 3 5 Deko3108S Repeater Mounted on Mounting Fixture 2 To lock the Repeater in to place insert four 5 16 NF hexagon screws supplied with the Re...

Страница 24: ...6 Mounted Deko3108S Rear View 3 5 GROUNDING WARNING ELECTRICAL SHOCK OR EQUIVALENT BE SURE THAT THE POWER IS NOT CONNECTED WHEN THE GROUND LUG IS UNSCREWED The protective grounding conductor is coppe...

Страница 25: ...uld point to the direction of the base station for maximum input power Verify that the antenna is in the base stations line of sight raise the antenna if necessary Install the donor antenna at a highe...

Страница 26: ...ing Isolation between Donor and Mobile Antennas The isolation between the Base Donor and Mobile Service antennas is critical especially for high gain outdoor applications For proper operation of the D...

Страница 27: ...from BTS at the Donor antenna port near the Repeater 2 Adjust the Donor antenna direction to receive the maximum signal strength 3 Compare the received signal strength with the calculated signal stre...

Страница 28: ...ther side of the cable will be connected to the Computer s Ethernet port for a local session as described in the following section 5 Interconnect the Repeater Ethernet port and the computer Ethernet p...

Страница 29: ...er the IP address 192 168 1 x where x can be any number between 2 and 250 inclusive For example 192 168 1 9 Define the subnet mask as shown 255 255 255 0 Click OK The computer communication parameters...

Страница 30: ...eater options CMU3108S NE specific options Deko3108S User management options Users The pane in the right side and the available tab options correspond to the item selected in the Topology Tree NOTE Th...

Страница 31: ...link path gain to a maximum value that is 10 dB below the isolation between the Base antenna and the Mobile antenna Use the Max Gain field for Downlink GAIN setting and the Gain Delta field to determi...

Страница 32: ...just the Gain Delta parameter this sets the delta between the uplink and downlink gain so the uplink gain is relatively lower than the downlink gain Click Send Repeat the procedure until the desired c...

Страница 33: ...may fine tune the position of the filter by lowering or increasing the channel start frequency by up to 500 KHz To fine tune the channel start frequency Select the Shift value from the drop down menu...

Страница 34: ...according to the selection If the input is invalid or out of range the following warning message will be displayed at the bottom of the window Status Error selected frequency exceed band limit 4 5 VI...

Страница 35: ...ndicating that the Panel Switch Mask parameter in the Config and Params tab section 4 3 is set to ON This does NOT indicate an error If the Panel Switch Mask parameter is set to OFF the corresponding...

Страница 36: ...NAL MODEM NOTE This section is relevant only if an external modem is to be connected 1 Click CMU in the left tree pane 2 The Deko CMU Configuration pane appears 3 Verify that the Communication paramet...

Страница 37: ...mestamp for each logged event and alarm To set the Repeaters date and time 1 Click on CMU in the tree pane 2 Click on Date Time in the menu bar The following dialog appears 3 Set the date and time par...

Страница 38: ...et up a Remote Wireless mode connection Disconnect the previously connected Ethernet cross cable from the computer Ethernet port and connect it to the external modem Ethernet port Connect the power ca...

Страница 39: ...ement application and the available functions These include Required network and modem parameters Monitoring alarms and troubleshooting Viewing the Logs 5 1 NAVIGATING THE USER INTERFACE The Dekolink...

Страница 40: ...k after completing the new data input and values update in any screen in order to insert the new values in the Repeater and implement the changes Refresh Click to refresh the current screen and update...

Страница 41: ...f the selected Repeater 1 Open and login to the Dekolink Web Access application 2 From the Tree Pane select the Deko CMU 3 Click Deko CMU Configuration The following parameters are relevant to be defi...

Страница 42: ...k Ack All The following table provides a description of the alarms displayed in the Alarms screen Alarm Description and probable cause Recommendation Power Above Threshold Malfunction in the Downlink...

Страница 43: ...nually as a result of an operator action Check RF Transmission box in the Controls and Parameters pane The box should be empty Click on it to change the LED status Caution First check for the reason f...

Страница 44: ...tion of any event that has occurred its originator when if they return and their type Note Set the clock in order to synchronize the events time of occurrence Click on Send Date Time To view the Deko...

Страница 45: ...nt parameters are displayed NOTE The Repeater Nickname field can be used to assign the module a recognizable name corresponding to the technology 5 5 1 Defining the Modem Connection Parameters WARNING...

Страница 46: ...lls the Dekolink CCD and the Deko CMU calls back the unit Enter the Local Phone Number of the Deko CMU Enter the Remote Phone Number of the CCD In the case of IP callback this is the phone number of t...

Страница 47: ...ed on the Repeater You may add new users modify or delete existing users 6 1 1 User Levels Three user levels are available Admin has access to all administration and configuration options including us...

Страница 48: ...select Users The list of users is displayed in the User s Pane 2 From the User s Pane click Add User The Add User dialog box is displayed 3 Enter the Login Name name used by user to login 4 Type the...

Страница 49: ...s removed from the list 6 2 CONFIGURATION BACKUP RESTORE AND UPLOAD The Repeater Web access application enables performing the following backup and restore operations via the Backup Restore dialog Bac...

Страница 50: ...d restore options The files are listed along with identifying information and the time of the backup Files of user defined configurations are BLUE The default factory settings file is BLACK and is nam...

Страница 51: ...e options 3 Select the file to be restored in the Repeater 4 Click Restore 5 After restore is complete click Reset 6 2 4 Restoring Factory Defaults 1 From the Tree Pane select the Repeater and click t...

Страница 52: ...lick Browse to browse for the upgrade file and click Open 3 Click Upload File s The updating process begins A message appears in The activity log box during the upload activity 4 Once the updating pro...

Страница 53: ...Range 0 dB to 34 dB in 1 dB steps 0 dB to 24 dB in 1 dB steps Composite Output Power 34dBm 1 24dBm 1 Composite Output Power per Band 28 dBm 1 21 dBm 1 Noise Figure Maximum Gain typical 5 dB 5 dB Prop...

Страница 54: ...High input power from Donor antenna Lower the input power by either setting the antenna to receive less power or by adding an attenuator at the BASE connector CAUTION Turn off disconnect from mains th...

Страница 55: ...r by act of vandalism or repaired or altered in any way that adversely affects its performance or reliability To obtain warranty service Purchaser may upon the prior written authorization of Dekolink...

Отзывы: