3. Technical specifications
3.1 Terminals
The SGC 120/121 uses three types of terminal blocks:
Connectors of 3.5 mm pitch
Connectors of 5.08 mm pitch
Connectors of 10.16 mm pitch
Table 3.1
Terminals
Connector type
Pitch
Male (on controller)*
Female (mating part)*
Quantity
4-pin
3.5 mm
5441294
5441430
2
6-pin
3.5 mm
5441317
5449283
1
8-pin
3.5 mm
5441320
5441456
1
10-pin
3.5 mm
5443962
5449306
1
2-pin
5.08 mm
5447353
5441980
1
4-pin
10.16 mm
5474274
5453499
2
*Note: Phoenix (Phoenix Contact (I) Pvt. Ltd.)
3.2 Power supply
Category
Specification
Controller terminals
1 (Ground)
2 (Battery or DC+)
Supply voltage range
Nominal voltage: 12/24 V DC
Operating range: 8 to 28 V DC
Cranking drop out period
50 ms
Maximum reverse voltage protection
-32 V DC
Measurement accuracy (battery voltage)
±1 % full scale
Resolution
0.1 V
Maximum current consumption
~ 200 mA, 12/24 V DC (excluding the current load for the DC and rotary
actuator's outputs)
Standby current consumption LCD backlight off)
124 mA, 12 V DC
123 mA, 24 V DC
Deep sleep current
20 mA, 12/24 V DC