IMD 100 Integration manual 4189360015 Rev. G
Operational procedures
Page 139 of 243
9.8
Manually activating the fan
It is possible to activate the fan manually by using function 17 in the special commands.
9.8.1 Prerequisites
None.
9.8.2 Activation
IMD Manager:
Select “17:Fan ON” in the “States and special commands” in the “Monitor and control”
tab.
CAN/CANopen:
send “
17
” to the special commands register (reg. 0x03)
The IMD will turn on the fan.
9.8.3 Operation
The fan remains ON until special command 18 is sent to the IMD.
9.8.4 Deactivation
IMD Manager:
Select “18:Fan Auto” in the “States and special commands” in the “Monitor and control”
tab.
Info
This function is not supported on IMD 122 A and IMD 122 B.