IMD 100 Integration manual 4189360015 Rev. G
Operational procedures
Page 135 of 243
ramp is set to Off, and the N cmd (ramp) is set to zero. This function has no effect on the N cmd (int)
and it is still possible to change the value of N cmd (int). As long as this function is enabled (NcR0) the
motor is held in position by the IMD.
9.5.1 Prerequisites
The IMD must be in state 1 (Normal operation).
9.5.2 Activation
HW input:
1. Connect the wire to either Di-1 or Di-2 terminals.
2. In the IMD Manager
“Configuration 1/3”,
set the logical input for the connected terminal to NcR0:
7. Select the polarity (active low or active high) depending on the source.
IMD Manager:
Do the same as for HW input. Set the NcR0 on by changing the polarity.
CAN/CANopen:
Set bit 1 in the Device mode register (Reg. 0x51, bit 1 = 1)
9.5.3 Operation
See description in the beginning of section
9.5.4 Deactivation
HW input:
the NcR0 will be deactivated when the polarity is changed to the not active polarity.
IMD Manager:
Change the polarity, or set the Input function of the logic input to
–Off–.
CAN/CANopen:
Reset bit 1 in the Device mode register (Reg. 0x51, bit 1 = 0)
1