operating manual
dry stove for pellet
DEFRO HOME SLIMPELL
translation of the original operating manual issue 5 June 2020
Страница 1: ...operating manual dry stove for pellet DEFRO HOME SLIMPELL translation of the original operating manual issue 5 June 2020 ...
Страница 2: ...zekazana wraz z piecem ko minkowym w przypadku odstąpienia własności innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME SLIMPELL Dry Stove if its construction has been changed without our permission or if the dry stove is used not in accordance with the operating manual This Declaration shall be handed over to a new owner along with the titl...
Страница 3: ... Warranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwi sowe Ruda Strawczyńska 103a 26 067 Strawczyn fax 41 303 91 31 serwis defro pl By sending back your Warranty Card you will be registered in our DE FRO heatingboilers users database and we will be able to provide you with quick and professional technical support If you do not send back a correctly filled in Warranty Card and t...
Страница 4: ...lue 14 7 2 Periodic inspection by authorized service 14 7 3 Dismantling of components 15 7 3 1 Doors disassembly 15 7 3 2 Window panel dismantling 15 7 4 Shutting the stove down 15 8 TROUBLESHOOTING 15 9 MEASURES IN CASE OF FIRE IN THE FLUE SOOT IGNITION 15 10 REMOVAL DUE TO WEAR OUT 16 11 REMARKS ON DRY STOVE USAGE 16 12 PRODUCT WARRANTY TERMS AND CONDITIONS 16 12 1 Warranty conditions 48h Servic...
Страница 5: ...his way 2 BASIC SAFETY RULES 2 1 SAFETY WARNINGS The national and local provisions should be met Equipment should be installed in compliance with the le gal standards applicable in the given location region or country The equipment should not be used by a person includ ing children of impaired physical sensory mental capa bilities and by persons without experience and required knowledge provided t...
Страница 6: ...s operating manual Check and clean flue gas discharge ducts connecting piece to flue periodically Store this manual carefully because it should be availa ble for a whole period of equipment operation In case of sale of giving the equipment to the other user you should always make sure whether the product has the manual enclosed Request a new copy from authorized sales outlet in DE FRO company if i...
Страница 7: ...adding made of vermiculite 10 grate 11 burner 12 ash pan 13 pellet container 14 pellet feeder 15 air pipe with igniter 16 flue gas outlet socket 17 flue gas fan unit 18 air intake socket air intake 19 air fan unit 20 bracket for wall mounting 21 temperature sensor pin 22 230 V power sup ply socket 23 body 1 2 4 3 5 6 18 16 20 21 22 24 1 7 2 8 10 9 11 12 1 7 2 9 14 15 13 19 18 17 16 23 ...
Страница 8: ... granulated product Ø 6 8 mm length of granulated product from 3 15 mm to 40 00 mm calorific value 16 5 MJ kg sulphur content max 0 03 moisture 10 ash content 0 7 bulk density 600 kg m3 During selection of the pellet user should pay special attention to fuel from unreliable sources on the possible content of contaminations in fuel in form of stones or other inflammable inclusions deteriorating qua...
Страница 9: ...ngcapacity In accordance with thePolishStandards each square meter of the floor slab in the single family building should transfer a load of 150 kg If this condition is fulfilled the dry stove manufactured by DEFRO can be installed without needing to reinforce the floor slab Picture 3 Minimum safe distances during setting of dry stove SLIM PELL Nonetheless if you are not sure about the design of f...
Страница 10: ...e occurrence of condensate For correct operation connector between the dry stove and flue or smoke duct should be executed acc to the below recommendations horizontal sections should have minimum slope 3 length of the horizontal section should be minimum and should not exceed 2 3 metre a number of changes of directions inclusive of use of the T component should not exceed 4 Picture 5 Example of co...
Страница 11: ...ENU and then select IGNITION b Choose the answer NO in the window displaying the question Is there fuel in the feeder c Confirm with the OK command Enter fuel manually d Select the option Activate the feeder on the next screen e When you hear the falling of pellets from the feeder pipe switch off the hopper by pressing again Activate the feeder or by selecting the IGNITION option From this moment ...
Страница 12: ...be cleaned in the presence of children 7 1 1 CLEANING BEFORE EACH STARTING Prior to every successive start up of the equipment the ash con tainer should be cleaned and emptied handling the ash with due care Remove ash pan for this purpose and remove the remaining dust Dust can be removed using vacuum cleaner only if it is completely cold Use vacuum cleaner adapted to remove the particles of a spec...
Страница 13: ...hangers at least once a month Soot removal improves the flow of smoke and quality of stove performance Unscrew fixing bolts of the lower deflector Remove bottom deflector unit Clean the removed deflector Up per deflector located in the furnace can be cleaned using brush or vacuum cleaner without disassembling Remove ash pan section 7 1 Remove six screws fixing the cover Clean space accessible behi...
Страница 14: ...tove prior to each heating season Pay special attention to the condition of gaskets replace them if necessary 7 1 8 FURNACE CHAMBER Clean furnace chamber of the stove periodically depending on moisture content and type of pellet used 7 1 9 FLUE In compliance with applicable regulations you should clean theflue two times a year The flue should be cleaned by a chimneysweep com pany and this fact sho...
Страница 15: ...rrect instal lation of the equipment without observation of the applicable building regulations or provisions of this manual or by external causes e g nat ural environment Below you will find the most frequent causes of incorrect of the equipment with their solutions No ignition in operating igniter Too much pellet in the burner No pellet in the container The furnace does not start Igniter does no...
Страница 16: ...e stove flammable materials cannot be located closer than 1500 mm from the stove Ash is to be put into heat resistant containers with a lid 11 After aheatingseason has finished thestove andsmokechannel are to be precisely cleaned 12 PRODUCT WARRANTY TERMS AND CONDITIONS 1 Placing warranty statement which contents correspond to the provisions of this document the Guarantor manufacturer of the produ...
Страница 17: ...lly re placed with non genuine used etc repairs outside the au thorized service of the Guarantor etc e damages are mechanical chemical thermal and they are not resulting from causes in the sold product f damages concerns wearing parts especially screws nuts handles ceramic and sealing elements g damages resulting from product usage inconsistently with the operating manual that is especially when i...
Страница 18: ...s with the admission of equipment user s warranty claims and does not end the complaint processing procedure DEFRO re serves the right to charge the equipment s user with component replacement repair costs which after expertise repair was stated as damaged by the factors independent of the boiler s manufac turer e g short circuit in electric system overvoltage flooding mechanical damages not visib...
Страница 19: ...equipment has been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card filled in has been familiarised with equipment s operation and maintenance city and data user signature filled by the manufacturer filled by the user The Customer and the instal...
Страница 20: ...20 14 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10 ...
Страница 21: ...equipment has been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card filled in has been familiarised with equipment s operation and maintenance city and data user signature filled by the manufacturer filled by the user The Customer and the instal...
Страница 22: ...22 ...
Страница 23: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm the removal of the fault I declare that I have familiarised myself with conditions of warrant...
Страница 24: ...24 ...
Страница 25: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm the removal of the fault I declare that I have familiarised myself with conditions of warrant...
Страница 26: ...26 ...
Страница 27: ...cian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm the removal of the fault I declare that I have familiarised myself with conditions of warrant...
Страница 28: ...28 ...
Страница 29: ...29 19 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of a chimneysweep date stamp and signature of a chimneysweep ...
Страница 30: ...sential characteristics Performance Technical specification CO emission in combustion products 0 0187 13 O2 73 235 1 mg m3 13 O2 PN EN 14785 2009 OGC emission in combustion products 6 9 1 mg m3 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion products 107 104 1 mg m3 13 O2 Commission Regulation EU 2015 1185 PM emission in combustion products 18 20 1 mg m3 13 O2 Commission Regula...
Страница 31: ...czyn Ruda Strawczyńska 103A PARAMETERS OF THE EQUIPMENT UNIT MODEL IDENTIFICATION SLIMPELL Energy efficiency class Direct thermal power kW Indirect thermal power kW 0 0 Energy efficiency Index EEI 126 Efficiency at nominal thermal power 90 9 Efficiency at minimal thermal power 96 6 Special precautions during assembly instal lation or maintenance of the equipment Consider guidelines included in the...
Страница 32: ...09 702 720 509 577 900 DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa 00 403 Warszawa ul Solec 24 253 Manufacturing plant Ruda Strawczyńska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro defro pl NIP 9591968493 ...