DeepSea Power & Light LED Matrix Скачать руководство пользователя страница 1

DEEPSEA

PO

WER & LIGHT

 

®

Operator’s Manual

T: 

(858) 576-1261

F: 

(858) 576-0219

4033 Ruffin Road

San Diego, CA 

92123- 1817 USA

www.deepsea.com

[email protected]

Original Instruction - 1

REV 10/31/13

LED Matrix

®

-3 SeaLite

®

Record product serial number below as it appears on the nameplate.

Serial #

Connector Type
Pin-outs

•  Postive = Pin        

•  Negative = Pin        

•  Ground = Pin        

•  Dimming (if applicable) = Pin        

LED Matrix

®   

- 3R SeaLite

®

Содержание LED Matrix

Страница 1: ...ego CA 92123 1817 USA www deepsea com sales deepsea com Original Instruction 1 REV 10 31 13 LED Matrix 3 SeaLite Record product serial number below as it appears on the nameplate Serial Connector Type Pin outs Postive Pin Negative Pin Ground Pin Dimming if applicable Pin LED Matrix 3R SeaLite ...

Страница 2: ...ater 1 53 kg 3 38 lbs Weight of Light Head Air 0 35 kg 0 8 lbs Water 0 23 kg 0 5 lbs Implodible Volume of the Ballast 737 42 cm3 45 in3 Environmental Specifications Depth Rating 6000 m 20 000 ft Test Pressure 10 000 psi Operation Temp 10º C to 40º C 14º F to 104º F Optical Specifications Color Red White Blue Lumens in the Water 18 000 Lumens Typical measured with all 3 light heads on Color Temp 69...

Страница 3: ...f Contents 3 Safety Symbols 4 General Notes Warnings 4 5 Pre Dive Inspection 5 Post Dive Inspection 5 Troubleshooting and Maintenance 5 6 Problems and Causes 5 6 External Maintenance 6 Recommended Spares 6 Optional Spares 6 Internal Maintenance 6 RMA Procedure for Repair 6 Limited Warranty 6 7 ...

Страница 4: ...y the head is tightly mated to the rear housing It is possible for some lights to partially flood and then reseal themselves while underwater Upon surfacing the light would then be internally pressurized a potentially dangerous situation Additionally if the power remains on when the light has partially flooded it is possible for electrolytic generation of an explosive mixture of hydrogen and oxyge...

Страница 5: ...ghten the connector until you feel the connector body engage the housing and then ap ply additional light torque to fully seat A loose connec tor may cause the light to flood 1 Engage the locking sleeve and tighten to finger tight never use a wrench 2 Turn on light to check operation Turn off and let cool before deployment 3 Check conditions of anodes Clean and replace as needed Post Dive Inspecti...

Страница 6: ...SS screws with AquaShield Lubricant 10 Replace Crash Guard Replace Screws Using a flat blade screw driver tighten to firm Internal Maintenance There are no field serviceable parts Return light to factory RMA Procedure for Repair Should it be necessary to return your light to the factory leave the connectors partially unscrewed For warranty and non warranty repairs please contact DeepSea Power Ligh...

Страница 7: ... Power Light Inc shall be to furnish new or repaired parts free of charge in exchange for parts which have been proved defective and does not include any other costs such as the cost of removal of the defective part installation labor or consequential damages of any kind the exclusive remedy being to require DeepSea Power Light Inc to furnish such new parts Under no circumstances shall the Buyer b...

Отзывы: