2 Technical characteristics
(1)
Heat exchanger inlet temperature: 80 °C (85 °C for CITY) - Domestic hot water temperature: 45 °C
(2)
DHW setting: 60 °C - Average domestic hot water temperature: 40 °C - Boiler setting: 80 °C (85 °C for CITY)
(3)
Cold water temperature: 10 °C - Pump in position 3
(4)
Swiss Directives
*
Specific flow:
Minimum average rise in temperature of 30K that the appliance can provide in the course of two successive draw-offs of 10 minutes
separated by a stop of 20 minutes.
**
Draw-off capacity
: Hot water flow at which water can be drawn off for a duration of 10 minutes with an average temperature elevation of 30 K.
3 Package list
Primary circuit - heating water
Maximum operating temperature
°C
90
Maximum operating pressure
bar
10
Maximum operating pressure in accordance
with W/TPW (4)
bar
6
Coil water capacity
l
6
Coil exchange surface
m
2
0.9
Secondary circuit - domestic water
Maximum operating temperature
°C
90
Maximum operating pressure
bar
10
Maximum operating pressure in accordance
with W/TPW (4)
bar
6
Water capacity
l
130
Weigh
Empty
kg
65.5
With water
kg
201.5
For shipping
kg
68.5
Performance
Boiler type
CITY
DPSM3 or
MC 15 LP/BS 130
DPSM3 or
MC 25 LP/BS 130
MCR 24
Useful boiler output
kW
24
14
23.6
24
Power exchanged (1)(3)
kW
24
14
23.6
22.6
Continuous flow (1)(3)
l/h
590
345
580
555
Specific flow* (2)(3)
l/min
20
18.5
20
16.5
Draw-off capacity**(2)(3)
l/10 mm
200
200
200
165
DHW tank package
Calorifier with sensors package
EE 22
Calorifier without sensors package
For Germany only
EE 30
Linking kit
:
- Boiler CITY
- DPSM or MC boiler
- Boiler MCR 24
EE 26
HC 13
HG 30
Sensor:
- Boiler CITY
- DPSM or MC boiler
- Boiler MCR 24
AD 138
AD 212
AD 226
Содержание SR 130