5.4.3.
Installing the deaerator
To guarantee optimum degassing of the oil feed line:
4
Fit the de-aerator with filter (delivered as standard).
4
Replace the filtration element (40 µm) before each heating season
It is imperative that you follow the recommendations and
instructions given in the manual for the deaerator.
CAUTION
The use of a fibre-based filter must be avoided at all costs.
We recommend mounting the deaerator outside the
boiler (A). If circumstances do not allow this, it is possible
to mount the deaerator inside the boiler (B).
B
A
C003144-F
30 kW
18 kW
24 kW
FloCo-Top
FloCo-Top
A
Mounting the deaerator outside the boiler
B
Mounting the deaerator inside the boiler
E
Marking on the hose intended for connection of the oil
supply
CAUTION
Connect the hose fitted with the blue ring marked
E
to the
oil supply fitting on the burner.
C004948-A
E
E
AFC 18 - AFC 24 - AFC 30
5. Installation
09/07/2015 - 300026439-07
45