5.3.2.
Fitting the boiler to a DHW tank
M002428-D
4
5
3
3
3
3
1. Put the DHW tank in place.
¼
Refer to the DHW tank’s installation, use and maintenance
instructions.
2. Carry out steps 1 to 8 described above.
¼
See chapter "Positioning the boiler on its own"
3. Lower the boiler from the transport pallet using lifting bars. Use
steel tubes 3/4" in diameter and 1400 mm in length.
4. Position the boiler on the DHW tank.
5. Put the retaining screws in place.
6. Refit the front panel.
5.3.3.
Positioning the boiler to the left or right of
a DHW tank
1. Put the DHW tank in place.
¼
Refer to the DHW tank’s installation, use and maintenance
instructions.
2. Put the boiler in place.
¼
See chapter "Positioning the boiler on its own".
AFC 18 - AFC 24 - AFC 30
5. Installation
09/07/2015 - 300026439-07
39