20
Expansion vessel
21
Ignition/ionization electrode
22
Air intake
3.3
Operating principle
3.3.1.
Skeleton Diagrams
1
Heat exchanger (Heating circuit)
2
Hydrobloc
3
Plate heat exchanger (DHW circuit) (Only on models with
domestic hot water production)
4
Heating flow
5
Domestic hot water outlet
6
Domestic cold water inlet
7
Heating return
8
Inverter valve
9
Shunt pump (Heating circuit)
10
Expansion vessel
3.3.2.
Shunt pump
H
Manometric height central heating circuit
Q
Water flow
The boiler is fitted with a modulating pump which is regulated by the
control panel as a fuction of ΔT.
The graph shows the manometric height at various outputs. The
parameters
MIN.PUMP SPEED
and
MAX.PUMP SPEED
are used to
modify the pump settings. If flow noise can be heard in the system, it
is possible to reduce the maximum pump speed with the parameter
MAX.PUMP SPEED
(First of all, vent the heating system). If
circulation in the radiators is too low or the radiators do not fully heat
up, increase the minimum pump speed with the parameter
MIN.PUMP SPEED
.
¼
See chapter: ""Professional" settings", page 82.
T001868-B
1
2
3
10
9
8
4
5
6
7
T002537-B
0
200
400
600
800
1000
1200
Q (l/h)
10 kW
15 kW
20 kW
25 kW
615
545
435
295
437
623
830
1037
0
100
200
300
400
500
700
H
(
mbar
)
600
3. Technical description
MCA 15 - MCA 25 MCA 25/28 MI
12
29/04/2010 - 300022146-001-B