DeDietrich EASYLIFE CFU 36 F30 Скачать руководство пользователя страница 1

EASYLIFE

S U S T A I N A B L E   C O M F O R T ®

MW

-2

0

0

1

0

5

0

5

8

-0

1

en

User Guide

Oil-fired boiler

CFU 36 F30

CFU 46 F30

Содержание EASYLIFE CFU 36 F30

Страница 1: ...EASYLIFE SUSTAINABLE COMFORT MW 200105058 01 en User Guide Oil fired boiler CFU 36 F30 CFU 46 F30...

Страница 2: ...sing the product and keep it in a safe place for later reference In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly Our service and customer...

Страница 3: ...8 6 3 Managing the central heating 19 6 3 1 Switching the central heating on off 19 6 3 2 Changing the room temperature temporarily override 19 6 3 3 Activating and configuring a timer programme for h...

Страница 4: ...Error codes 31 8 4 Alarm codes 32 8 5 Resetting the burner safety unit 32 8 6 List of burner faults 32 9 Environmental 33 9 1 Disposal and recycling 33 9 2 Energy savings 33 10 Warranty 34 10 1 Genera...

Страница 5: ...al sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involv...

Страница 6: ...d professionals are permitted access to the inside of the appliance in accord ance with the prevailing electrical safety standard Caution Power the appliance via a circuit that includes an omnipolar s...

Страница 7: ...em perature of the radiators may exceed 60 C Caution Take precautions with the domestic hot water Depending on the boiler settings the domestic hot water temperature may exceed 65 C Important Insulate...

Страница 8: ...ion and standards Carry out initial commissioning and any checks necessary Explain the installation to the user If maintenance is necessary warn the user of the obligation to check the appliance and k...

Страница 9: ...CQ0004 3 1 2 Oil categories Tab 4 Type of oil that can be used Maximum viscosity Domestic fuel oil with a low sulphur content 50 mg kg EL 6 mm2 s at 20 C Domestic fuel oil with a low sulphur content w...

Страница 10: ...and low temperature re gime 1 P1 kW 11 6 14 5 Seasonal space heating energy efficiency s 86 86 Useful efficiency at rated heat output and high temperature regime 2 4 87 3 86 9 Useful efficiency at 30...

Страница 11: ...ssembled and pre set oil burner Electronic control panel Chimney connection Flue gas discharge via a chimney type connection 4 2 Boiler 1 Control panel 2 On Off switch 3 Burner manual reset button 4 D...

Страница 12: ...eral pages Each page enables direct access to a zone Display the home screen by turning the selector to the right All the zone symbols and names can be changed 1 Boiler symbol 2 Boiler flow temperatur...

Страница 13: ...he central heating on off Domestic Hot Water On Off Switching domestic hot water production on off Heating temperature Setting the activities temperature Water temperature Modifying the domestic hot w...

Страница 14: ...Installer Menu not accessible to the user Finder Menu not accessible to the user Signals status set points Menu not accessible to the user Energy counter Monitoring the energy consumption Settings Pe...

Страница 15: ...heating temperatures Setting the temperatures for the activities Operating mode Selecting the operating mode Time programmes heating Activating and configuring a timer programme Zone2 only if the SCB...

Страница 16: ...gs Modifying the domestic hot water set point temperatures CH function on Switching the central heating on off DHW function on Switching domestic hot water production on off Outdoor temperature Force...

Страница 17: ...absence or going on holiday page 22 5 4 Frost protection Caution The frost protection function does not work if the boiler is powered off Caution The integrated protection system only protects the bo...

Страница 18: ...ating periods Display settings AP104 HMI contrast value Setting the screen brightness AP105 Unit displayed Selecting the unit displayed 0 for C 1 for F AP124 Child lock Prevents children from accident...

Страница 19: ...ched off for all circuits This can lead to energy savings for example during the summer period 1 Go to the menu Central heating On Off Tab 18 Type of access Access path Direct access from the main hom...

Страница 20: ...be modified 5 Carry out the following actions according to your needs Modify the timings for programmed activities Add a new time range Delete a programmed activity Copy programmed daily activities to...

Страница 21: ...erates with two set point temperature parameters DHW comfort setpoint DHW reduced setpoint These set point temperatures can be modified as required 1 Go to the menu Water temperature Tab 24 Type of ac...

Страница 22: ...emperature and domestic hot water temperature can be reduced to save energy To do this activate the System holiday mode operating mode for all zones including for domestic hot water 1 Go to the menu S...

Страница 23: ...2 Changing the name and symbol of a zone The names and symbols of the various zones are factory configured It is possible to personalise the name and symbol for the installation zones 1 Go to the men...

Страница 24: ...ab 32 Example Start of the activity Activity Room temperature set point 6 30 Morning 1 20 C 9 00 Away 2 19 C 17 00 Home 3 20 C 20 00 Evening 4 22 C 23 00 Sleep 5 16 C 6 7 2 Changing the name of an act...

Страница 25: ...eter Parameter name for the Zone1 or for the Zone2 only if the SCB 04 optional PCB is connected Sleep CP080 Room setpoint temperature of the user zone activity Can be set from 5 C to 30 C Home CP081 R...

Страница 26: ...rsion information Tab 38 Type of access Access path Direct access from the main home screen Not available Quick access from any screen Press the key Select Version information Tab 39 PCB Available inf...

Страница 27: ...tructions 7 3 1 Check the hydraulic pressure 1 Checking the hydraulic pressure in the installation 2 If the hydraulic pressure is less than 0 08 MPa 0 8 bar top up the level of water in the heating in...

Страница 28: ...key Select Test mode 2 Select one of the following parameters Tab 42 Parameter name Parameter Description ChimneyModeStatus Status of the Chimney mode 0 Off 2 Medium power System Flow Temp AM016 Flow...

Страница 29: ...iators Work from the lowest to the highest 7 Open the venting valve with the bleed key keeping a cloth pressed against the vent Warning The water may still be hot 8 Wait until water comes out of the v...

Страница 30: ...perating errors If the boiler malfunctions a code is displayed on the main screen of the control panel This code is important for the correct and rapid diagnosis of the type of malfunction and for any...

Страница 31: ...ot match CU type H02 09 Partial block Partial blocking of the device recognized H02 10 Full Block Full blocking of the device recognized H02 16 Int CSU Timeout Internal CSU Timeout H02 25 ACI error AC...

Страница 32: ...shorted or measures a temperature above range A00 34 TOutside Missing Outside temperature sensor was expected but not detected A00 81 RoomTempMissing Room Temperature sensor was expected but not detec...

Страница 33: ...t flow connection fitted the wrong way round Stop valves closed Filter or strainer on the tank clogged Oil tank empty Pump noises The pump is drawing in air The pump is idling Poor combustion hygiene...

Страница 34: ...ts found to be defective by our technical services team Other countries Our warranty is valid for two years All countries Except Germany and Russia Your appliance is covered by a contractual guarantee...

Страница 35: ...correctly is poorly maintained or not maintained at all or is not installed correctly it is your responsibility to ensure that installation is carried out by a qualified installer In particular we can...

Страница 36: ...of the products in relation to building size and characteristics Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C Seasonal space heating energy efficiency class...

Страница 37: ...rated is related to the preferential space heater Tab 54 Weighting of boilers Psup Prated Psup 1 2 II package without hot water storage tank II package with hot water storage tank 0 0 0 0 1 0 3 0 37 0...

Страница 38: ...11 Appendix 38 CFU 7740570 v04 03112022...

Страница 39: ...al and technological information contained in these technical instructions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior...

Страница 40: ...nik com 0800 201608 freecall NEUBERG S A LU www neuberg lu www dedietrich heating com 352 0 2 401 401 39 rue Jacques Stas B P 12 L 2549 LUXEMBOURG THERMEA Czech Republic s r o CZ www dedietrich cz 420...

Отзывы: